Tools Required
• | J 43763 Torque Converter Leak Test
Plug |
• | J 21369-F Torque Converter Leak
Test Fixture |
Important: The torque converter leak test requires a
large container of water in order to submerge the torque converter.
- Position torque converter (6) on the work table so that the pump hub
is facing up.
- Move nut (3) to the middle of the center body (1) of J 43763
.
- Install J 43763
into the torque
converter hub.
- Install J 21369-F
(3)
onto torque converter (8) and onto J 43763
(4).
- Firmly tighten nut (6) in order to seal J 43763 into the
torque converter.
- Firmly tighten nut (5) in order to securely attach the torque converter
to J 21369-F
(3). Connect an air hose
to air fitting (1) of J 43763
.
- Pressurize the converter to 517 kPa (75 psi) maximum.
- Disconnect the air hose. Submerge the torque converter in water.
- Closely observe the torque converter for bubbles that indicate leakage.
If the torque converter leaks, replace the torque converter.
Caution: All pressure from the torque converter must be exhausted before loosening the
test fixture nut. Failure to relieve the pressure could cause personal injury and/or
property damage.
- Push on pressure relief valve (2) of J 43763
and release the air from the torque converter.
- Remove the J tools from the torque converter.