Table 1: | Wheels and Tires |
Table 2: | Capacities |
Please refer to Recommended Fluids and Lubricants for more information. All capacities are approximate. When adding see the refrigerant charge label under the hood for charge capacity information and requirements.
Engine | VIN Code | Spark Plug Gap |
---|---|---|
VORTEC 4300 V6 | W | 0.060 inches (1.52 mm) |
VORTEC 4800 V8 | V | 0.040 inches (1.01 mm) |
VORTEC 5300 V8 | T | 0.040 inches (1.01 mm) |
VORTEC 6000 V8 | U | 0.040 inches (1.01 mm) |
VORTEC 8100 V8 | G | 0.060 inches (1.52 mm) |
Model | Description | Torque |
---|---|---|
C/K 1500 & C/K 2500 | 6 Bolts (14 mm) | 140 lb ft (190 N·m) |
C/K 3500 | 8 bolts (14 mm) | 140 lb ft (190 N·m) |
Tire Pressure | See the Certification/Tire label on the rear edge of the driver's door or the incomplete vehicle document in the cab. |
Application | Capacities | |
---|---|---|
English | Metric | |
Cooling System | ||
After refill, the level must be rechecked. See "Cooling System" in the Index. | ||
| 15.0 quarts | 14.0 L |
| 15.0 quarts | 14.0 L |
| 15.0 quarts | 14.0 L |
| 15.5 quarts | 15.0 L |
| 15.0 quarts | 14.0 L |
| 13.0 quarts | 13.0 L |
| 13.0 quarts | 13.0 L |
| 16.0 quarts | 16.0 L |
| 16.0 quarts | 16.0 L |
| 27.0 quarts | 26.0 L |
| 27.0 quarts | 25.0 L |
* Vehicles equipped with the optional engine oil cooler. | ||
Engine Oil With Filter | ||
After refill, the level must be rechecked. Add enough engine oil so that the fluid is within the proper operating range. See Engine Oil . | ||
| 4.5 quarts | 4.3 L |
| 6.0 quarts | 5.7 L |
| 6.0 quarts | 5.7 L |
| 6.0 quarts | 5.7 L |
| 6.5 quarts | 6.1 L |
Fuel Tank | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Air Conditioning Refrigerant Capacity | ||
|
|
|
Table 1: | Hybrid Specifications |
Table 2: | Capacities |
Maximum Output Power | 2.4 kw |
Output Voltage | 120 VAC +5% -8% measured at the outlets |
Current Output (Maximum Continuous) | 20 Amps |
Output Frequency | 60 Hz ± 0.25 Hz |
Total Harmonic Distortion (THD) | <=10% |
Overload Protection Level | 21 A(rms) current limit for 5 seconds |
Ground Fault Detection Level | >=6ma |
Application | Capacities | |
---|---|---|
English | Metric | |
Hybrid Cooling System | 2.1 quarts | 2.0 L |
After refill, the level must be rechecked. |