Tools Required
• | J 43763 Torque Converter Leak Test
Plug |
• | J 21369-F Torque Converter Leak
Test Fixture |
Important: The torque converter leak test requires a
large container of water in order to submerge the torque converter.
- Position the torque converter (6) on the work table so that the pump
hub is facing up.
- Move the nut (3) to the middle of the center body (1) ofJ 43763
.
- Install J 43763
into the torque
converter hub.
- Install J 21369-F
(3)
onto the torque converter (8) and onto J 43763
(4).
- Firmly tighten the nut (6) in order to seal J 43763 into
the torque converter.
- Firmly tighten the nut (5) in order to securely attach the torque
converter to J 21369-F
(3). Connect an
air hose to the air fitting (1) of J 43763
.
- Pressurize the converter to 517 kPa (75 psi) maximum.
- Disconnect the air hose. Submerge the torque converter in water.
- Closely observe the torque converter for bubbles that indicate leakage.
If the torque converter leaks, replace the torque converter.
Caution: All pressure from the torque converter must be exhausted before loosening the
test fixture nut. Failure to relieve the pressure could cause personal injury and/or
property damage.
- Push on the pressure relief valve (2) ofJ 43763
and release the air from the torque
converter.
- Remove the J tools from the torque converter.