Removal Procedure
- Loosen the outlet duct clamps at the air cleaner assembly and the turbocharger.
- Remove the air cleaner outlet duct.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
Important: The air cleaner outlet duct must be fully seated against the positive stop feature on the turbocharger inlet.
- Install the air cleaner outlet duct.
- Tighten the outlet duct clamps at the turbocharger and the air cleaner assembly.
Tighten
Tighten the clamps to 4 N·m (35 lb in).