GM Service Manual Online
For 1990-2009 cars only

Circuit Description

The fuel rail temperature (FRT) sensor is a variable resistor that measures the temperature of the fuel in the CNG fuel rail. The fuel injector control module (FICM) supplies 5 volts to the FRT signal circuit and supplies a ground to the low reference circuit. The FICM monitors the FRT sensor voltage and communicates the data to the PCM by a dedicated pulse width modulated (PWM) circuit. This DTC sets when the FRT signal voltage is below the normal operating range of the sensor.

Conditions for Running the DTC

    • The ignition is ON.
    • DTC P1207 is not set.

Conditions for Setting the DTC

    • The fuel rail temperature sensor voltage is less than 0.1 V.
    • The condition exists for more than 5 seconds.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Diagnostic Aids

    • Use the Temperature vs Resistance table in order to test the FRT sensor at various temperature levels in order to evaluate the possibility of a skewed sensor. A skewed sensor could result in a driveability condition. If the engine has sat overnight, the FRT sensor and the intake air temperature values should display within a few degrees. If the temperatures are not within 3°C (5°F), refer to Fuel Rail Temperature Sensor Output Voltage Versus Temperature Resistance .
    • For an intermittent condition, refer to Intermittent Conditions .

Step

Action

Values

Yes

No

Schematic Reference: Engine Controls Schematics

Connector End View Reference: Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check Alternative Fuels - Engine Controls?

--

Go to Step 2

Go to Diagnostic System Check - Alternative Fuels (Engine Controls)

2

  1. Turn ON the ignition, with the engine OFF.
  2. Observe the FRT parameter with a scan tool.

Does the scan tool indicate that the FRT is less than the specified value?

0.1 V

Go to Step 4

Go to Step 3

3

  1. Observe the Freeze Frame and/or the Failure records data for this DTC.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame and/or the Failure records data.

Does the DTC fail this ignition cycle?

--

Go to Step 4

Go to Diagnostic Aids

4

  1. Disconnect the harness connector of the FRT sensor. Refer to Fuel Temperature Sensor Replacement .
  2. Turn ON the ignition, with the engine OFF.
  3. Observe the FRT parameter with a scan tool.

Does the scan tool indicate that the FRT sensor voltage is more than the specified value?

4.6 V

Go to Step 6

Go to Step 5

5

  1. Turn OFF the ignition.
  2. Test the signal circuit of the FRT sensor for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems in the C/K Pickup Service Manual.

Did you find and correct the condition?

--

Go to Step 8

Go to Step 7

6

Replace the FRT sensor. Refer to Fuel Injection Fuel Rail Fuel Pressure Sensor Replacement .

Did you complete the replacement?

--

Go to Step 8

--

7

Replace the FICM. Refer to Fuel Injector Control Module Replacement .

Did you complete the replacement?

--

Go to Step 8

--

8

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30  seconds.
  3. Turn ON the ignition, with the engine OFF.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 2

Go to Step 9

9

With a scan tool, select Capture Info in order to observe the stored information.

Does the scan tool display any DTCs that you have not diagnosed?

--

Go to Diagnostic Trouble Code (DTC) List

System OK