The Alternative Fuels ECM contains data storage areas. The Alternative Fuels ECM runs a test on the stored data called a checksum. This DTC indicates a failure has occurred within the Alternative Fuels ECM.
The ignition switch is ON.
The Alternative Fuels ECM monitors an internal malfunction.
The Alternative Fuels ECM will switch-over to gasoline fuel operation. Alternative fuel operation will not be attempted until the next ignition key cycle.
• | The Alternative Fuels ECM will illuminate the MIL and store the DTC as History during 1 drive trip in which the diagnostic runs and fails. |
• | The Alternative Fuels ECM will record operating conditions at the time the DTC sets. This information will be stored as Freeze Frame data. |
• | The Last Test Failed status will clear when the DTC runs and passes. |
• | The Alternative Fuels ECM will turn OFF the MIL after 3 consecutive drive trips that the DTC runs and passes. |
• | The History status will clear after 40 consecutive WARM-UP cycles with NO failures of ANY DTC. |
• | All DTC Information can be cleared with a scan tool. |
The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Alternative Fuels Engine Controls Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Alternative Fuels (Engine Controls) |
Replace the Alternative Fuels ECM. Refer to Alternative Fuels Engine Control Module Replacement . Did you complete the replacement? | Go to Step 3 | -- | |
3 |
Does the scan tool indicate the diagnostic passed? | System OK | Go to Diagnostic System Check - Alternative Fuels (Engine Controls) |