TFP Valve Position Switch Resistance Check
Step
| Action
| Value(s)
| Yes
| No
|
Important: Whenever the transmission 20-way connector is disconnected and the engine
is running, multiple DTCs will set. Be sure to clear these codes when you
are finished with this procedure.
Important: This procedure tests the Automatic Transmission Fluid Pressure Manual
Valve Position Switch (TFP Val. Position Sw.) circuits and the Automatic Transmission
Fluid Temperature (TFT) Sensor circuit. Do not use this procedure to test
other Automatic Transmission circuits. Refer to the
Automatic Transmission Wiring Harness Check
.
|
1
|
- Install the J 39775
Jumper Harness on the transmission side of the 20-way connector.
- Using the J 39200
Digital Multimeter (DMM) and the J 35616-A
Connector Test Adapter Kit, measure the resistance from terminal
N to the transmission case.
Is the resistance greater than the specified value?
| 50 K ohms
|
Go to Step 3
|
Go to Step 2
|
2
|
- Disconnect the TFP Val. Position Sw. from the Automatic Transmission
Wiring Harness Assembly (A/T Wiring Harness Assembly).
- Measure the resistance from terminal C of the TFP Val. Position
Sw. to the switch housing.
Is the resistance greater than the specified value?
| 50 K ohms
|
Go to Step 16
|
Go to Step 19
|
3
| Measure the resistance from terminal R to the transmission
case.
Is the resistance less than the specified value?
| 200 ohms
|
Go to Step 5
|
Go to Step 4
|
4
|
- Disconnect the TFP Val. Position Sw. from the A/T Wiring Harness
Assembly.
- Measure the resistance from terminal E of the TFP Val. Position
Sw. to the switch housing.
Is the resistance less than the specified value?
| 200 ohms
|
Go to Step 16
|
Go to Step 19
|
5
| Measure the resistance from terminal P to the transmission
case.
Is the resistance greater than the specified value?
| 50 K ohms
|
Go to Step 7
|
Go to Step 6
|
6
|
- Disconnect the TFP Val. Position Sw. from the A/T Wiring Harness
Assembly.
- Measure the resistance from terminal D of the TFP Val. Position
Sw. to the switch housing.
Is the resistance greater than the specified value?
| 50 K ohms
|
Go to Step 16
|
Go to Step 19
|
7
|
- Start the engine.
- Allow the engine to idle.
- Set the parking brake.
- Place the gear selector in Reverse.
- Measure the resistance from terminal N to the transmission case.
Is the resistance less than the specified value?
| 200 ohms
|
Go to Step 8
|
Go to Step 16
|
8
|
- Place the gear selector in Low (D1).
- Measure the resistance from terminal N to the transmission case.
Is the resistance less than the specified value?
| 200 ohms
|
Go to Step 9
|
Go to Step 16
|
9
|
- Place the gear selector in Manual Third (D3).
- Measure the resistance from terminal R to the transmission case.
Is the resistance greater than the specified value?
| 50 K ohms
|
Go to Step 10
|
Go to Step 16
|
10
|
- Place the gear selector in Drive (D4).
- Measure the resistance from terminal P to the transmission case.
Is the resistance less than the specified value?
| 200 ohms
|
Go to Step 11
|
Go to Step 16
|
11
|
- Place the gear selector in Manual Second (D2).
- Measure the resistance from terminal P to the transmission case.
Is the resistance greater than the specified value?
| 50 K ohms
|
Go to Step 12
|
Go to Step 16
|
12
|
- Turn the ignition OFF.
Important: The resistance of the TFT Sensor is temperature dependent, and therefore
varies far more than any other device. Refer to Transmission Fluid Temperature
Sensor in
Electronic Component Description
.
- Measure the resistance from terminal L to terminal M (TFT Sensor) of
the J 39775
Jumper Harness.
Is the resistance within the specified range?
| 3088-3942 ohms @ 20°C
(68°F)
159-198 ohms @ 100°C (212°F)
|
Go to Step 13
|
Go to Step 14
|
13
|
- Measure the resistance from terminal L to the transmission case.
- Measure the resistance from terminal M to the transmission case.
Are both resistances greater than the specified value?
| 10 M ohms
| System
OK
|
Go to Step 14
|
14
|
- Disconnect the TFP Val. Position Sw. from the A/T Wiring Harness
Assembly.
Important: The resistance of the TFT Sensor is temperature dependent, and therefore
varies far more than any other device. Refer to Transmission Fluid Temperature
Sensor in
Electronic Component Description
.
- Using the J 39200
DMM, measure the resistance between terminal A and terminal B of the TFP Val.
Position Sw. (TFT Sensor).
Is the resistance within the specified range?
| 3088-3942 ohms @ 20°C
(68°F)
159-198 ohms @ 100°C (212°F)
|
Go to Step 15
|
Go to Step 19
|
15
|
- Measure the resistance from TFP Val. Position Sw. terminal A to
the transmission case.
- Measure the resistance from TFP Val. Position Sw. terminal B to
the transmission case.
Are both resistances greater than the specified value?
| 10 M ohms
|
Go to Step 16
|
Go to Step 19
|
16
| Inspect for high resistance or a short:
• | Inspect the A/T Wiring Harness Assembly. for poor electrical connections
at the automatic transmission 20-way connector, and at the TFP Val. Position
Sw. Look for the following conditions: |
- | A broken wire inside the insulation |
• | If diagnosing for an intermittent condition, massage the wiring
harness while watching the test equipment for a change. |
Did you find high resistance or a short?
| --
|
Go to Step 1
|
Go to Step 17
|
17
|
- Disconnect the TFP Val. Position Sw. from the A/T Wiring Harness
Assembly.
- Inspect the following circuits for an open or short:
Did you find an open or shorted condition?
| --
|
Go to Step 18
|
Go to Step 19
|
18
| Replace the A/T Wiring Harness Assembly.
Refer to TCC PWM Solenoid, TCC Solenoid, and Wiring Harness Replacement.
Is the replacement complete?
| --
|
Go to Step
1
| --
|
19
| Replace the TFP Val. Position Sw.
Refer to Valve Body and Pressure Switch Replacement.
Is the replacement complete?
| --
|
Go to Step
1
| --
|