- Test for leak points if water has leaked into the interior.
- Mark the location of any leaks.
- If a leak has not been found, perform the following steps:
• | Close all the windows and the vents. |
• | Cover the air lever in position in order to use the outside air. |
• | Place the air lever in position in order to use the outside air. |
• | Turn the fan lever to the HI position. |
• | Run a small stream of water over the area suspected of leaking. |
• | Inspect for pressure bubbles which indicate that air is escaping
from the interior. |
- Use an air drying body sealing compound if the leak is between
the body panels.
- Inspect the door alignment if the leak is near the door. In order
to perform the door alignment, refer to Door Adjustment
in Doors.
- Make sure the weatherstrip is not damaged.
Ensure that the weatherstrip is properly seated on the opening flange.
- Replace the weatherstrip if needed.