Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Generator on-vehicle test which will test the generator
independently from the vehicle wiring.
|
1
| Perform the charging
system check. Refer to
Charging System Check
Has the charging system check been performed?
| --
| Go to
Step 2
| --
|
2
|
- Connect the red alligator clip of a J 41450-B
CS Generator Electronic Tester to the generator output terminal.
(The output wire is attached to the generator with a ring terminal and nut.)
- Connect the black alligator clip of the J 41450-B
to the metal generator housing. The
green POWER lamp of the tester should light and remain lighted while the tester
is being used.
Does the green POWER lamp on the tester light?
| --
| Go to
Step 9
| Go to
Step 3
|
3
|
- Recheck the alligator clip connections that were made in Step
2.
- Correct the connections if they were reversed.
Does the green POWER lamp on the tester light after the correct connections
are verified?
| --
| Go to
Step 9
| Go
to
Step 4
|
4
| Connect a digital multimeter (DMM) from the generator output terminal
to the generator metal housing.
Is the voltage above the specified value?
| 12 V
| Go to
Step 18
| Go to
Step
5
|
5
| Use a DMM to check the voltage between the battery terminals.
Is the voltage above the specified value?
| 12 V
| Go to
Step 6
| Go to
Step
8
|
6
|
- Inspect the circuit between the generator output terminal and
the battery positive terminal for a loose connection or open circuit condition.
- If a loose connection or open circuit was located, repair it.
Is the circuit okay between the generator output terminal and the battery
positive terminal?
| --
| Go to
Step 7
| --
|
7
| Repair the loose connection or open circuit between the battery negative
terminal and the generator housing.
Is the repair complete?
| --
| Go to
Step
2
| --
|
8
|
- Inspect the battery. Refer to
Battery Load Test
.
- Charge or replace the battery if necessary.
Is the battery OK?
| --
| Go to
Step 2
| --
|
9
|
- Leave the J 41450-B
alligator clips attached as in Step 2, and disconnect the vehicle
4-way generator connector.
- Locate the matching 4-way connector of the J 41450-B
and connect it to the generator.
Does the red DIAGNOSTIC lamp on the tester light?
| --
| Go to
Step 11
| Go to
Step 10
|
10
| Perform the following test of the DIAGNOSTIC lamp of the
J 41450-B
:
- Disconnect the J 41450-B
4-way connector from the generator.
- Prepare a jumper wire with an in-line 100 ohm resistor. The watt
rating of the resistor is not important. (An inexpensive 100ohms resistor
can be purchased at an electronics supply store.)
- At one end of the prepared jumper wire, attach a Metri-Pack 150
male terminal probe adapter from a J 35616
Connector Test Adapter Kit.
- Connect the prepared jumper wire to the J 41450-B
L terminal (which is called the B
terminal on CS 130D, LR, and AD generators). The tester connector terminals
are the same as the generator connector terminals, so terminal identification
on the J 41450-B
can
be accomplished by referring to
Engine Electrical Connector End Views
.
- Connect the other end of the jumper to the battery negative terminal.
Does the red DIAGNOSTIC lamp on the tester light when the jumper is
connected?
| --
| Go to
Step 19
| Go to
Step 18
|
11
|
- Prior to connecting a carbon pile load tester, make sure that
the load dial of the carbon pile tester is turned completely to the OFF position.
- Connect the cable leads of the carbon pile tester to the battery
of the vehicle.
- Connect an inductive ammeter to the output lead(s) of the generator.
Make sure that all output leads pass through the ammeter inductive clip. The
carbon pile tester may have its own inductive ammeter, or use a J 35590
Current Clamp.
- Start the engine and allow the engine to idle briefly.
Did the red DIAGNOSTIC lamp on the J 41450-B
light?
| --
| Go to
Step 19
| Go to
Step 12
|
12
| Increase the engine speed to 2500 RPM.
Does the red DIAGNOSTIC lamp on the J 41450-B
light?
| --
| Go to
Step 19
| Go to
Step 13
|
13
| Turn on the load of the carbon pile tester, and increase the load until
the generator output is equal to the load test value given in
Generator Usage
.
As the load is increased, is the generator capable of producing the
amount of load test current specified in
Generator Usage
?
| --
| Go to
Step 14
| Go to
Step 19
|
14
| Maintain generator operation at the load test value.
Is the red DIAGNOSTIC lamp on the J 41450-B
lighted?
| --
| Go to
Step
19
| Go to
Step 15
|
15
|
- Continue to operate the generator at the load test value.
- Connect a DMM from the generator output terminal to the battery
positive (+) terminal.
Is the voltage above the specified value?
| 0.5 V
| Go to
Step 22
| Go to
Step
16
|
16
|
- Continue to operate the generator at the load test value.
- Connect a DMM from the generator metal housing to the battery
negative (-) terminal.
Is the voltage above the specified value?
| 0.5 V
| Go to
Step 23
| Go to
Step
17
|
17
|
- Disconnect the DMM.
- Turn OFF the load in the carbon pile tester.
- Turn the ignition switch to LOCK to stop the engine.
- Disconnect the carbon pile tester cables from the battery.
- Disconnect the J 41450-B
4-way connector from the generator.
- Inspect the generator 4-way connector on the vehicle.
Does the vehicle have a wire in the L terminal cavity (or B terminal
for CS 130D, LR, and AD generators) of the generator 4-way connector?
| --
| Generator OK
| Go to
Step 24
|
18
| There is
an internal problem in the J 41450-B
. Replace the J 41450-B
.
Has the J 41450-B
been
replaced?
| --
| Go to
Step 2
| --
|
19
|
Important: In addition to generator repair or replacement, the L terminal circuit
(if applicable) must be tested for resistance in order to avoid a repeat failure.
- Repair or replace the generator. Refer to
Generator Replacement
.
- Disconnect and examine the generator 4-way connector.
Is there a wire in the L cavity (or B cavity for CS 130D, LR, and AD
generators) of the generator connector?
| --
| Go to
Step
20
| Go to
Step 2
|
20
|
- Be sure the 4-way generator connector is disconnected.
- Turn the ignition key to the RUN position.
- Connect a fused jumper wire (with a 5 amp fuse) from ground to
the vehicle 4-way generator connector terminal L (or B terminal for CS 130D,
LR, and AD generators). Refer to
Engine Electrical Connector End Views
.
Does the fuse blow?
| --
| Go to
Step
21
| Go to
Step 2
|
21
| There is a short to B+ voltage when the ignition key is in the RUN position.
The short may be a result of a miswired condition. The L terminal circuit
must be a resistance circuit either through a charge indicator or the
PCM. If direct battery voltage is applied to the generator at the L terminal,
the regulator will eventually be destroyed, causing a repeat failure.
- Repair the short to voltage in the L terminal circuit (or B terminal
circuit for CS 130D, LR, and AD generators).
- Connect the 4-way connector to the generator.
Is the repair complete?
| --
| Generator OK
| --
|
22
|
- Turn off the engine.
- Disconnect the battery negative terminal.
- Inspect the circuit between the battery positive terminal and
the generator output terminal for a high-resistance connection. Disassemble
and clean all connections in this circuit.
- Assemble the connections and tighten to specifications.
- Connect the battery negative terminal. Tighten to specifications.
Refer to
Fastener Tightening Specifications
.
Is the repair complete?
| --
| Go to
Step
2
| --
|
23
|
- Turn off the engine.
- Inspect the ground circuit for high resistance from the battery
negative terminal to the generator housing. Disassemble and clean all connections.
- Assemble the connections and tighten to specifications. Refer
to
Fastener Tightening Specifications
.
Is the repair complete?
| --
| Go to
Step
2
| --
|
24
| The tester turns the generator on in a different way than the vehicle
does, so an additional test is necessary.
- Remove the 4-way connector from the generator.
- Measure the generator internal resistance between the L and I/F
terminals (B and C terminals for CS 130D, LR, and AD generators). Use terminal
adapters in a J 35616
Connector Test Adapter Kit. The L and I/F terminals are the two middle
terminals on the generator.
Is the resistance between the generator I/F and L terminals equal to
or below the specified value?
| 500 ohms
| Generator OK
| Go to
Step
19
|