The PCM supplies a voltage of about 450 mV between the Heated Oxygen Sensor (HO2S) high and low signal circuits. The oxygen sensor varies the voltage over a range from about 1,000 mV when the exhaust is rich, down through about 10 mV when the exhaust is lean.
The PCM monitors and stores the HO2S voltage information. The PCM evaluates the HO2S voltage samples in order to determine the amount of time the HO2S voltage was out of range. The PCM compares the stored HO2S voltage samples taken within each sample period and determines if majority of the samples are out of the operating range.
The PCM monitors the HO2S voltage for being fixed above a predetermined voltage. If the PCM detects the voltage is above a predetermined voltage, a DTC will set.
• | DTCs P0101, P0102, P0103, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0200, P0335, P0336, P0351-P0358, P1258 not set. |
• | The ignition voltage is greater than 9.0 volts. |
• | The fuel system operating in Closed Loop. |
• | The fuel trim learn is enabled. |
• | The AIR, EGR, and the Catalyst diagnostics are not active. |
• | The TP angle is between 2% and 70%. |
• | The HO2S signal voltage remains above 775 mV. |
• | The conditions are present for 33 seconds. |
• | The PCM illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The PCM records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the PCM stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the PCM records the operating conditions at the time of the failure. The PCM writes the conditions to the Freeze Frame and updates the Failure Records. |
• | The PCM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A last test failed, or current DTC, clears when the diagnostic runs and does not fail. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Use a scan tool in order to clear the MIL and the DTC. |
Important: Remove any debris from the PCM connector surfaces before servicing the PCM. Inspect the PCM connector gaskets when diagnosing/replacing the PCM. Ensure that the gaskets are installed correctly. The gaskets prevent water intrusion into the PCM.
• | Leaking Fuel Pressure Regulator. |
• | Check the HO2S electrical connections for evidence of water intrusion. Water present in the connector causes the B+ supply to the heater to bleed over to the signal circuit. |
• | Fuel pressure: The system goes rich if the pressure is too high. The PCM compensates for some increase. However, if the fuel pressure is too high, a DTC may set. Refer to Fuel System Diagnosis . |
• | Rich injector(s): Perform the Injector Balance Test. Refer to Fuel Injector Balance Test with Tech 2 or Fuel Injector Balance Test with Special Tool . |
• | Leaking injector: Refer to the Fuel System Diagnosis . |
• | Evaporative emissions (EVAP) canister purge. Check the canister for fuel saturation. If full of fuel, check the canister control and hoses. Refer to Evaporative Emission Control System Operation Description . |
• | MAF sensor: Disconnect the MAF sensor and see if the rich condition is corrected. If so, check for proper installation. If installed OK, replace the MAF sensor. If the MAF sensor is installed backwards, the system goes rich. The plastic portion of the sensor has arrows cast into it indicating proper air flow direction. The arrows must point toward the engine. |
• | An oxygen supply inside the HO2S is necessary for proper operation. The HO2S wires provides the supply of oxygen. Inspect the HO2S wires and connections for breaks or contamination. Refer to Heated Oxygen Sensor Wiring Repairs in Wiring Systems. |
• | TP sensor: An intermittent TP sensor output causes the system to go rich, due to a false indication of the engine accelerating. For an intermittent condition, refer to Symptoms . |
The numbers below refer to the step numbers on the diagnostic table.
This step is verifying the condition is present. The engine must be at the normal operating temperature before performing this test. For any test that requires probing the PCM or a component harness connector, use the Connector Test Adapter Kit J 35616 . Using this kit prevents damage to the harness connector terminals. Refer to Using Connector Test Adapters in Wiring Systems.
Using the Freeze Frame and/or Failure Records data may aid in locating an intermittent condition. If you can not duplicate the DTC, the information included in the Freeze Frame and/or Failure Records data can help determine how many miles since the DTC set. The Fail Counter and Pass Counter can also be used to determine how many ignition cycles the diagnostic reported a pass and/or a fail. Operate the vehicle within the same freeze frame conditions (RPM, load, vehicle speed, temperature etc.) that the PCM recorded. This will isolate when the DTC failed. Refer to Symptoms .
If the voltage remains high, this indicates the signal circuit is shorted to a voltage. If the voltage goes low, this indicates a rich condition.
This step isolates the condition. If the voltage remains high, this indicates the signal circuit is not shorted to the heater feed circuit.
Review the system mechanization. Test for a short between the HO2S signal circuit and any other wires powered by this fuse that run together inside the same harness.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
Is the HO2S voltage greater than the specified value? | 775 mV | |||
Does the scan tool indicate that this diagnostic failed this ignition? | -- | Go to Diagnostic Aids | ||
Is the HO2S voltage greater than the specified value? | 775 mV | Go to Diagnostic Aids | ||
Remove the HO2S heater fuse while monitoring the HO2S voltage. Does the voltage drop to within the specified range when the power to the heater is disconnected? | 350-550 mV | |||
6 |
Does the scan tool indicate the HO2S voltage within the specified range? | 350-550 mV | ||
7 |
Important: Disconnecting the PCM may eliminate the short to voltage if the signal circuit is shorted to another C1 circuit.
Is a voltage present? | -- | ||
Repair the short to voltage in the HO2S signal circuit. Refer to Heated Oxygen Sensor Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | ||
9 |
Important: Program the replacement PCM. Refer to Powertrain Control Module Replacement/Programming . Replace the PCM. Is the action complete? | -- | -- | |
10 | Replace the HO2S. Refer to Heated Oxygen Sensor Replacement - Bank 2 . Is the action complete? | -- | -- | |
11 |
Does the scan tool indicate that this test ran and passed? | -- | ||
12 | Select the Capture Info option and the Review Info option using the scan tool. Does the scan tool display any DTCs that you have not diagnosed? | -- | Go to the applicable DTC table | System OK |