Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test lamp light? | -- | ||
2 | Locate and repair the open in CKT 1324 (LT GRN) between the lamp and the rear lamps bussing block. Is the repair complete? | -- | System OK | -- |
3 | Connect a self-powered test lamp from terminal B of the inoperative lamp connector to ground. Does the test lamp light? | -- | ||
4 | Replace the lamp. Is the repair complete? | -- | System OK | -- |
5 | Locate and repair the open in CKT 1750 (BLK) between the lamp and the rear lamps bussing block. Is the repair complete? | -- | System OK | -- |