Scan Tool Data Definitions
Not all parameters will apply to each vehicle. Use only the parameters
which apply to your particular vehicle.
1-2 Solenoid -- (ON/OFF): The scan tool indicates whether this shift solenoid in the automatic
transmission is commanded ON by the vehicle control module (VCM).
2-3 Solenoid -- (ON/OFF): The scan tool indicates whether this shift solenoid in the automatic
transmission is commanded ON by the VCM.
3-2 Downshift Solenoid -- (ON/OFF): The scan tool indicates whether this shift solenoid in the automatic
transmission is commanded ON by the VCM.
4WD -- (Enable/Disable): The scan tool indicates enabled when four wheel drive has been
selected by the operator.
4WD Low -- (Enable/Disable): The scan tool indicates enabled when four wheel drive low has been
selected by the operator.
A/C Evaporator Switch -- (Open/Closed): The A/C evaporator switch is an input to the VCM that determines
when pressure has reached a calibrated threshold. The VCM uses this switch
as the primary input for determining when to command the A/C compressor
ON or OFF.
A/C Sec. High Pres. Switch -- (Open/Closed): The secondary high pressure switch closes when the A/C systems
high pressure limit is approached. The VCM monitors the state of this switch
for compressor and auto recirculation operation. The switch closes at
a high pressure value which is calibrated for specific platforms.
The VCM continuously monitors the secondary high pressure switch
when A/C has been selected by the operator.
A/C Relay -- (ON/OFF): The scan tool indicates whether the A/C relay control circuit has
been commanded ON by the VCM. The A/C relay provides power to control the
A/C compressor clutch. It will indicate YES when the relay is commanded
ON.
A/C Request -- (YES/NO): The scan tool indicates the state of the A/C request input circuit.
The VCM uses the A/C request signal in order to determine whether A/C compressor
operation has been requested by the operator.
Actual EGR Position -- Range (0-100 Percent): The actual EGR position indicates the actual exhaust gas recirculation
(EGR) valve pintle position as a percentage. A fully closed valve would be
displayed as 0 percent.
Air Fuel Ratio -- Range (0.0:1-25.5:1): The scan tool indicates the VCM calculated air to fuel ratio. The
typical air to fuel ratio is 14.7:1.
AIR Pump Relay -- (ON/OFF): The scan tool indicates the state of the air pump relay. The relay
will be ON only during Closed Loop.
Barometric Pressure (BARO )-- Range (0-5 Volts): The barometric pressure (BARO) represents a measurement of the
barometric air pressure. This measurement is determined by using the manifold
absolute pressure (MAP) sensor in order to determine manifold
vacuum. This function is performed when the ignition is selected from
OFF to ON, and during high throttle angle operations when manifold pressure
equals ambient barometric pressure. This parameter is scaled in volts
which is the raw output from the MAP sensor prior to being converted
by the VCM to kPa.
Barometric Pressure (BARO) -- Range (62 kPa-104 kPa): The VCM calculates the displayed BARO parameter from the MAP sensor
when the ignition is selected from OFF to ON and at a wide open throttle (WOT)
conditions. The BARO parameter represents local ambient barometric
pressure. The VCM uses the displayed BARO reading in order
to compensate engine fueling differences for changes in altitude. This
parameter is scaled in kilo pascals (k/pa).
Brake Switch -- Range (APPLIED/RELEASED): The brake switch indicates the status of the brake switch. Applied
would indicate the brake pedal has been depressed.
Closed Loop (CL) Since Restart -- (YES/NO): The Closed Loop Since Restart indicates whether or not the vehicle
has been in a Closed Loop state during the current ignition cycle.
Clutch Pedal Switch -- (Applied/Released): The scan tool indicates the current clutch switch state. When the
clutch pedal is applied, the clutch switch will indicate ON.
CMP Retard -- Range (0-90 degrees): The CMP retard indicates a correction to the camshaft position
(CMP) sensor and the crankshaft position (CKP) sensor relationship caused
by small tolerance variations or component misalignment.
Cruise -- (Enable/Disable): The cruise parameter indicates if the driver has requested cruise
control.
Cycles of Misfire Data -- Range (0-100): Displays an increasing count of crankshaft revolutions from 0 to
100. It will reset to 0 after reaching 100.
Decel Fuel Mode -- (Active/Inactive): The scan tool indicates whether the vehicle is in decel fuel cutoff
mode. This mode is generally entered during long decels to prevent catalyst
overheating and excessive tailpipe emissions.
Desired EGR Position -- Range (0-100 Percent): The Desired EGR Position indicates the desired exhaust gas recirculation
(EGR) pintle position in a percentage. Zero percent indicates a closed
EGR valve. One hundred percent is a fully opened EGR valve.
Desired IAC Position -- Range (0-255) Counts: The desired IAC position indicates how much the idle air control
(IAC) valve is commanded open by the VCM. Zero counts would indicate a commanded
fully closed valve. Two hundred fifty five counts would indicate a commanded
fully opened valve.
Desired Idle Speed -- Range (0-3,187 RPM): The VCM commands the Desired Idle Speed by controlling the IAC.
The VCM compensates for various engine loads by controlling IAC in order
to maintain the desired idle speed.
DTC Set this Ignition -- (YES/NO): The scan tool indicates whether or not any DTC has set during the
current ignition cycle.
ECT -- Range -40°to 215°C (-40° to 419°F): The engine coolant temperature (ECT) sensor is mounted in a coolant
passage in the intake manifold. The VCM monitors the engine temperature as
the ECT sensor responds to temperature changes in the engines coolant.
ECT Sensor -- Range (0-5 Volts): The engine coolant temperature (ECT) sensor is mounted in a coolant
passage in the intake manifold. The VCM monitors the engine temperature as
the ECT sensor responds to temperature changes in the engines coolant.
This parameter is scaled in volts and is the raw voltage from the ECT
detected by the VCM on the signal circuit.
EGR Duty Cycle -- Range (0-100 Percent): The EGR duty cycle determines the percentage of time the EGR valve
control circuit has 12 volts applied to it. This is a method to control the
current applied to the valve motor. As duty cycle increases, so does
current which forces the valve to open further and allow more exhaust
gas to enter the intake. One hundred percent duty cycle would
indicate a fully opened valve.
EGR Sensor -- Range (0-5 Volts): The EGR Sensor indicates the actual EGR pintle position, as detected
by the VCM, scaled in voltage. A low voltage indicates a closed valve.
Engine Load -- Range (0-100 Percent): The VCM determines the engine load based upon the engine speed
and MAF sensor readings. Engine load increases with any increase in RPM or
airflow.
Engine Run Time -- Range (0:00:00-18:12:15) Hours: Minutes:
Seconds: The engine run time is a measure of how long the engine has run
during this ignition cycle. When the engine stops running, the timer resets
to zero.
Engine Speed -- Range (0-16,384 RPM): The VCM computes the engine speed from the CKP sensor input.
EVAP Canister Purge -- (OFF/ON): The evaporative emission (EVAP) canister purge pulls a small vacuum
on the entire evaporative emission system. The scan tool displays if the EVAP
canister purge solenoid valve is currently OFF or ON. When the
scan tool displays ON, manifold vacuum is being applied to the system.
EVAP Duty Cycle -- Range (0-100 Percent): The scan tool indicates the EVAP duty cycle that the VCM is commanding.
The EVAP duty cycle is a pulse width modulated (PWM) voltage applied to the
purge valve which is displayed as a percentage. A high percentage of
EVAP duty cycle would indicate near maximum canister purging.
EVAP Vent Solenoid -- (Closed/Open): The scan tool will show the status of the EVAP vent solenoid. A
closed EVAP vent solenoid would indicate the evaporative system is being tested
for leaks.
Excess Vacuum Test -- (Pass/Not Run/Fail): The Excess Vacuum Test will fail if fuel tank vacuum builds at
an excessive rate during normal EVAP canister purge. A restricted vent
valve or vent valve hoses will cause improper venting. The scan
tool display states for this parameter are Pass and Not Run/Fail.
Fuel Level -- Range (0-100 Percent): The scan tool indicates as a percentage the level of fuel in the
fuel tank. As the sender float position changes, the fuel level sensors signal
voltage changes. The VCM converts this voltage into a percentage of
fuel remaining in the fuel tank.
Fuel Level Sensor -- Range (0-5 Volts): The scan tool will display the fuel level sensor signal voltage
which varies with fuel level.
Fuel Tank Pressure -- Range (-20-7 in H2O): The scan tool displays the vapor pressure measured in the fuel
tank by the fuel tank pressure transducer. The VCM converts the raw voltage
signal from the sensor into a pressure scale displayed by the scan tool.
Fuel Tank Vacuum Pressure Volts -- Range (0-5 Volts): The scan tool displays the vapor pressure voltage measured in the
fuel tank by the fuel tank pressure transducer.
Fuel Trim Cell -- Range (0-22) Cell: Twenty-two separate cells contain MAP and RPM values from a range
of engine operating conditions. Each cell determines fuel requirements for
a specific operating condition that the engine is running within. Examples
would be idling, accelerations, road load cruise, or decelerations.
Fuel Trim Enable -- (YES/NO): This parameter indicates when the VCM is using fuel trim values
to adjust fuel delivery to the engine. Fuel trim will be disabled when the
vehicle is not in Closed Loop, malfunction codes related to
fuel trim are set, large amounts of purge vapor are ingested
by the engine, or additional diagnostics that temporarily affect
fuel trim operation are active.
HO2S BN 1 Sen. 1 -- Range (0-1 Volts): The HO2S BN 1 Sen. 1 indicates the voltage activity of the heated
oxygen sensor (HO2S) bank 1 sensor 1.
HO2S BN 1 Sen. 2 -- Range (0-1 Volts): The HO2S BN 1 Sen. 2 indicates the voltage activity of the HO2S
bank 1 sensor 2.
HO2S BN 1 Sen. 3 -- Range (0-1 Volts): The HO2S BN 1 Sen. 3 indicates the voltage activity of the HO2S
bank 1 sensor 3.
HO2S BN 2 Sen. 1 -- Range (0-1 Volts): The HO2S BN 2 Sen. 1 indicates the voltage activity of the HO2S
bank 2 sensor 1.
HO2S BN 2 Sen. 2 -- Range (0-1 Volts): The HO2S BN 2 Sen. 2 indicates the voltage activity of the HO2S
bank 2 sensor 2.
HO2S Xcounts Bn 1 -- Range (0-255): The HO2S Xcounts Bn 1 increments each time that the HO2S bank
1 sensor 1 crosses the 450 MV threshold. This number resets to zero
after it reaches the limit of 255.
HO2S Xcounts Bn 2 -- Range (0-255): The HO2S Xcounts B2 increments each time that the HO2S bank 2
sensor 1 crosses the 450 MV threshold. This number resets to zero
after it reaches the limit of 255.
HVAC in Recirculation Mode -- (ON/OFF): If the secondary high pressure switch closes, indicating high refrigerant
pressures, auto recirculation will be commanded ON by the VCM. This will prevent
warm outside air from entering the vehicle which might further raise
the A/C refrigerant pressures.
IAC Position -- Range (0-255) Counts: The scan tool displays in counts the idle air control (IAC) pintle
position commanded by the VCM. The higher the number of counts, the larger
the air passage opening. The idle air control should
respond fairly quickly to changes in engine load in order to maintain
desired idle RPM.
Intake Air Temperature (IAT) -- Range (-40° to 151°C): The VCM converts the signal voltage of the intake air temperature
(IAT) sensor into degrees. The VCM uses the intake air temperature in order
to adjust fuel delivery and spark timing according to the incoming air
temperature.
Intake Air Temperature (IAT) Sensor -- (0-5 Volts): The VCM monitors the intake air temperature (IAT) sensor for voltage
changes. This parameter displays the raw voltage signal detected by the VCM.
The VCM uses the intake air temperature in order to adjust fuel delivery
and spark timing according to the incoming air temperature.
Ignition 1 -- Range (0.0-25.5 Volts): The ignition 1 parameter indicates the voltage level on the Ignition
input to the VCM. The normal ignition 1 voltage is approximately 13.8 volts,
but may vary between 11-16 volts.
Ignition 1 Low -- (YES/NO): The scan tool indicates when low ignition voltage has been detected
by the VCM. A low ignition 1 voltage may degrade ignition timing
and injector operation. The normal ignition 1 voltage
is approximately 13.8 volts, but may vary between 11-16 volts.
Ignition 1 High -- (YES/NO): The scan tool indicates when high ignition voltage has been detected
by the VCM. An excessively high ignition 1 voltage could damage electronics
and electrical components. The normal ignition 1 voltage
is approximately 13.8 volts, but may vary between 11-16 volts.
Ignition 1 ON -- (YES/NO): The ignition 1 ON parameter indicates when the VCM is detecting
ignition voltage. The normal ignition voltage is approximately 13.8 volts,
but may vary between 11-16 volts. The VCM monitors
the ignition voltage to compensate for low voltage operation
of the injectors and to increase the dwell time of the ignition
coil.
Inj. PWM Average Bank 1 -- Range (0-499 ms): The Inj. PWM Avg. Bank 1 indicates the VCM commanded injector ON
time, measured in milliseconds.
Inj. PWM Average Bank 2 -- Range (0-499 ms): The Inj. PWM Avg. Bank 2 indicates the VCM commanded injector ON
time, measured in milliseconds.
KS Adjust Factor -- Range (-90-90°): The knock sensor (KS) is a piezoelectric device which detects vibration
due to spark knock. The VCM monitors the knock sensor signal while it performs
spark advance calculations. This allows the engine to operate at maximum
spark advance without spark knock to improve driveability and
fuel economy. This parameter is the number of degrees
Knock Retard -- Range (0.0-90 degrees): The KS retard indicates the amount of spark advance the VCM is
removing in order to control spark knock.
Knock (KS) Sensor -- Range (4.5-5.0 Volts): The scan tool indicates the current knock sensor nominal voltage
detected by the VCM. This parameter is not an indication of the level of spark
knock.
Knock (KS) Sensor Activity -- Range (0-255 Counts): The knock sensor activity will display a randomly fluctuating number
between 0 and 255 when the VCM detects spark knock. This random number will
be unchanging when NO knock is present.
Long Term Fuel Trim (FT) Bn 1 -- Range (0-255 Counts): The long term fuel trim (FT) is derived from the short term fuel
trim value. The VCM uses the long term fuel trim for the long-term correction
of the fuel delivery. A value of 128 counts indicates
that the fuel delivery requires NO compensation to maintain
a 14.7:1 air to fuel ratio. A value below 128 counts means
that the fuel system is too rich and the fuel delivery is being
reduced, requiring decreased injector pulse width. A value above
128 counts indicates that a lean condition exists. The
VCM compensates by adding fuel, increasing the injectors pulse width.
Long Term Fuel Trim (FT) Bn 1 -- Range (Percentage of Compensation
Required): The long term fuel trim (FT) is derived from the short term fuel
trim value. The VCM uses the long term fuel trim for the long-term correction
of the fuel delivery. A value of 128 counts indicates
that the fuel delivery requires NO compensation to maintain
a 14.7:1 air to fuel ratio. A value below 128 counts means
that the fuel system is too rich and the fuel delivery is being
reduced, requiring decreased injector pulse width. A value above
128 counts indicates that a lean condition exists. The
VCM compensates by adding fuel, requiring increased injector pulse
width. As fuel compensation is required, the difference between commanded
long term fuel trim and 128 counts will be displayed as a percentage.
Long Term Fuel Trim (FT) Bn 2 -- Range (0-255 Counts): The long term fuel trim (FT) is derived from the short term fuel
trim value. The VCM uses the long term fuel trim for the long-term correction
of the fuel delivery. A value of 128 counts indicates
that the fuel delivery requires NO compensation to maintain
a 14.7:1 air to fuel ratio. A value below 128 counts means
that the fuel system is too rich and the fuel delivery is being
reduced, requiring decreased injector pulse width. A value above
128 counts indicates that a lean condition exists. The
VCM compensates by adding fuel, requiring increased injector pulse
width.
Long Term Fuel Trim (FT) Bn 2 -- Range (Percentage of Compensation
Required): The long term fuel trim (FT) is derived from the short term fuel
trim value. The VCM uses the long term fuel trim for the long-term correction
of the fuel delivery. A value of 128 counts indicates
that the fuel delivery requires NO compensation to maintain a 14.7:1
air to fuel ratio. A value below 128 counts means that
the fuel system is too rich and the fuel delivery is being reduced,
requiring decreased injector pulse width. A value above 128 counts
indicates that a lean condition exists. The VCM compensates
by adding fuel, requiring increased injector pulse width. As fuel
compensation is required, the difference between commanded long term
fuel trim and 128 counts will be displayed as a percentage.
Loop Status -- (Open Loop/Close Loop): The loop status indicates when the VCM is controlling fuel delivery
which is calculated using the HO2S bank 1 and 2 inputs. This is called Closed
Loop fuel control. During Open Loop, the VCM ignores the HO2S input
and bases fuel delivery upon throttle position (TP), engine
coolant, and mass air flow (MAF) sensor input.
MAF -- Range (0-512 g/s): The VCM converts the mass air flow (MAF) sensor signal input from
frequency into grams per second. The MAF indicates the amount of air entering
the engine.
MAF Frequency -- Range (Frequency in Hertz): The MAF produces a frequency as it measures airflow entering the
engine. The VCM detects this frequency on the signal circuit and converts
it into a grams per second (g/s) of airflow scale. This raw frequency
can be displayed by the scan tool as it is detected by the VCM.
Manifold Absolute Pressure (MAP) -- Range (10 kPa-104 kPa): The manifold absolute pressure (MAP) sensor measures the change
in intake manifold pressure caused by engine load and engine speed changes.
During wide open throttle (WOT), MAP will be maximum. During decel,
vacuum will be high in the intake and MAP will be displayed at its minimum
pressure.
Manifold Absolute Pressure (MAP) -- Range (0.0-5.0 Volts): The MAP sensor produces a low signal voltage when the manifold
pressure is low. A low MAP voltage indicates a high vacuum in the intake manifold.
The MAP sensor produces a high signal voltage when the manifold
pressure is high. A high MAP voltage indicates a low vacuum
in the intake manifold. With the ignition ON and the engine
OFF, the manifold pressure equals the ambient atmospheric pressure.
This will produce a relatively high MAP signal voltage. The VCM uses
this information as an indication of the vehicle altitude.
This parameter is referred to as the BARO.
Mileage Since DTC Clear -- Range (Km/Mi): The scan tool indicates the total distance the vehicle has traveled
since the diagnostic trouble codes (DTCs) were cleared.
Misfire Current Cyl. #1-#8 -- Range (Current Counts): The scan tool displays the number of misfires detected during each
200 crankshaft revolution sampling period. Each cylinder has its own register
to record misfires that have occurred. If the Misfire Current Cyl is
incrementing, it will be reset to zero after 200 crankshaft revolutions.
If the misfire DTC has set, the number of misfires in the register will
be added to the Misfire History cycle register each time the current
cycle register is reset to zero.
Misfire History Cyl. #1-#8 -- Range (Counts): The scan tool displays a record of misfires that have occurred
since the misfire DTC was set. This parameter will be summed with the current
cylinder register each time the 200 crankshaft revolution sample is
reset to zero if the current misfire test block exceeds an allowable
misfire threshold.
PCM/VCM in VTD Fail Enable -- (YES/NO): This parameter will indicate when the VCM detects a vehicle theft
deterrent (VTD) failure after the vehicle was running. VCM in VTD Fail Enable
will indicate YES if this occurs and will allow future operation of
the vehicle without shutting OFF fuel when the vehicle is started. Normal
conditions with NO DTCs set will display this parameter as NO.
Pre HO2S -- (Not Ready/Ready): The scan tool will display Not Ready until the VCM has commanded
Closed Loop. The heated oxygen sensor (HO2S) is then considered ready for
operation.
Post HO2S -- (Not Ready/Ready): The scan tool will display Not Ready until the VCM has determined
that the post HO2S is sufficiently warm for full operation.
Power Enrichment -- (Active/ Inactive): The Power Enrichment parameter indicates if the Power Enrichment
mode is active. Power enrichment fueling is entered during high engine load
operation to provide for maximum engine output.
Powertrain DTC Set -- (YES/NO): The scan tool displays if a current or history powertrain DTC is
set.
Purge Leak Test -- (Pass/Not Run/Fail): The Purge Leak Test parameter indicates if the evaporative system
leak test has Passed or Not Run/Failed.
Reference Pulse Occurred -- (YES/NO): The scan tool will indicate a YES after a CKP sensor reference
pulse has been detected by the VCM.
Rich/Lean Bn 1 -- (Rich/Lean): The Rich/Lean Bn 1 parameter indicates the oxygen content in the
exhaust gases in bank 1. Rich indicates low oxygen content, lean indicates
high oxygen content.
Rich/Lean Bn 2 -- (Rich/Lean): The Rich/Lean Bn 2 parameter indicates the oxygen content in the
exhaust gases in bank 2. Rich indicates low oxygen content, lean indicates
high oxygen content.
Short Term Fuel Trim (FT) Bn 1 -- Range (0-255 Counts): The short term fuel trim was formerly the fuel integrator. The
short term fuel trim represents a short-term correction to the fuel delivery
by the VCM in response to the amount of time the HO2S voltage
spends above or below the 450 mV threshold. An HO2S
voltage reading below 450 mV indicates a lean air to
fuel mixture. If the HO2S voltage averages below the 450 mV
threshold, the short term fuel trim counts increase in order
to add fuel. If the HO2S voltage averages above the 450 mV threshold,
the VCM reduces the fuel delivery in order to compensate for
the indicated rich condition.
Short Term Fuel Trim (FT) Bn 1 -- Range (Percentage of Compensation
Required): The short term fuel trim was formerly the fuel integrator. The
short term fuel trim represents a short-term correction to the fuel delivery
by the VCM in response to the amount of time the HO2S voltage
spends above or below the 450 mV threshold. As fuel
compensation is required, the difference between commanded short term
fuel trim and 128 counts will be displayed as a percentage.
Short Term Fuel Trim (FT) Bn 2 -- Range (0-255 Counts): The short term fuel trim was formerly the fuel integrator. The
short term fuel trim represents a short-term correction to the fuel delivery
by the VCM in response to the amount of time the HO2S voltage
spends above or below the 450 mV threshold. An HO2S
voltage reading below 450 mV indicates a lean air to
fuel mixture. If the HO2S voltage averages below the 450 mV
threshold, the short term fuel trim counts increase in order
to add fuel. If the HO2S voltage averages above the 450 mV threshold,
the VCM reduces the fuel delivery in order to compensate for
the indicated rich condition.
Short Term Fuel Trim (FT) Bn 2 -- Range (Percentage of Compensation
Required): The short term fuel trim was formerly the fuel integrator. The
short term fuel trim represents a short-term correction to the fuel delivery
by the VCM in response to the amount of time the HO2S voltage
spends above or below the 450 mV threshold. As fuel
compensation is required, the difference between commanded short term
fuel trim and 128 counts will be displayed as a percentage.
Small Leak Test -- (Pass/Not Run/Fail): The Small Leak Test runs immediately after the Weak Vacuum Test.
The EVAP system is closed and the fuel tank vacuum is monitored by the VCM.
A slow loss of vacuum rate will cause this test to fail. This
test will indicate either Pass or Not Run/Failed.
Spark -- Range (-96 Degrees to -255 Degrees): The spark advance is a display of the spark advance calculation
which the VCM is provided to the ignition control module (ICM). The VCM calculates
the desired spark advance using data such as engine temperature,
RPM, load, and vehicle speed.
Spark Control -- (Advance/Retard): The spark control parameter indicates whether the VCM is advancing
or retarding spark.
Start Up ECT -- Range -40° to 215°C (-40°
to 419°F): The VCM records the engine coolant temperature when the engine
is started.
Startup IAT -- Range -40° to 151°C (-40°
to 304°): The VCM records the intake air temperature when the engine is started.
TCC Enable -- (YES/NO): The scan tool indicates whether or not the VCM commanded the torque
converter clutch (TCC) solenoid to an active state.
TCC Duty Cycle -- Range (0-100 Percent): The scan tool indicates the duty cycle that the VCM has commanded
to control the TCC solenoid. The TCC solenoid is pulse width modulated to
provide a determined amount of pressure, which is displayed
as a percentage of the supply pressure. This provides for smooth TCC
engagement.
TFP Switch A/B/C Range -- (ON/OFF)(ON/OFF)(ON/OFF): The A/B/C Range parameter indicates the current state of the transmission
range switch. These are pressure switches internal to the transmission.
Total Misfire Current Count -- Range (0-255): The Total Misfire Current Count indicates the total number of cylinder
firing events that the VCM detected as being misfires during the last 200
crankshaft revolution sample period. Misfire is diagnosed using
crankshaft speed variations in relation with engine speed
and load data.
Total Misfire Failures -- Range (0-255): The Total Misfire Failures indicates the total number of cylinder
firing events that the VCM determined as misfires during the last 200 crankshaft
revolution sample.
Total Misfire Passes Since First Failure -- Range (0-65,535): The Total Misfire Passes Since First Fail indicates the total number
of cylinder firing events that the VCM detected as being good since the misfire
DTC was set.
TP Angle -- Range (0-100 Percent): The VCM computes the TP angle from the TP signal voltage input.
This is an indication of throttle blade angle demanded by the operator. The
TP angle should read 0 percent at idle. At 0 percent,
the TP voltage will read below 0.90 volts. The TP angle
should read 100 percent at wide open throttle (WOT).
Throttle Position (TP) Sensor -- Range (0-5 Volts): The VCM uses the throttle position in order to determine the amount
of throttle demanded by the operator of the vehicle. The TP sensor reads between
0.36-0.96 volts at idle to above 4.0 volts
at wide open throttle (WOT).
TR Switch -- Range (One of the following P R N D4 D3 D2 D1): The trans range (TR) switch indicates the trans range selected
by the operator.
Valid Ref. Pulse Occurred -- (YES/NO): The scan tool will indicate YES after 2 or more CKP sensor reference
pulses have been detected by the VCM.
Vehicle Speed-km/h -- Range (0-255): The vehicle speed parameter indicates in mph or km/h how fast the
drive wheels are turning.
VTD Auto Learn Timer -- (Active/Inactive): The auto learn timer will indicate if the vehicle theft deterrent
(VTD) system is currently in the auto learn mode. The auto learn mode requires
approximately 10 minutes to complete.
VTD Fuel Disable -- (Active/Inactive): If the VCM has not received the correct password from the passlock
module or body control module, if equipped, the VCM will disable fuel to
the fuel system. If this occurs, the scan tool will display Active.
VTD Fuel Disable Until Ign. OFF -- (YES/NO): With the ignition ON and a VTD code stored, the scan tool will
display YES.
Weak Vacuum Test -- (Pass/Not R/F): The Weak Vacuum Test will run only if the Loaded Canister Test
does not pass. Insufficient vacuum in the evaporative system will cause this
test to fail. The two states of this parameter are Pass and Not Run/Fail.