Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Functional Check? | -- | Go to Step 2 | Go to Functional Check | ||||||||||
2 | Inspect for the following conditions:
Does the malfunction still exist? | -- | Go to Step 3 | Go to Functional Check | ||||||||||
3 |
Is the airflow high? | -- | Go to Step 4 | Go to Step 7 | ||||||||||
4 | Does the airflow change with different blower speeds? | -- | Go to Step 5 | Go to Step 11 | ||||||||||
5 | Perform the System Performance Test. Refer to System Performance Test . Is the heater output temperature correct? | -- | Go to Step 6 | Go to Step 12 | ||||||||||
6 |
Is the repair complete? | -- | Go to Functional Check | -- | ||||||||||
7 | Perform the function test. Refer to System Performance Test . Is the repair complete? | -- | Go to Functional Check | Go to Step 8 | ||||||||||
8 | Check the airflow from the vent outlets. Is the airflow from the vent outlets high? | -- | Go to Step 9 | Go to Step 17 | ||||||||||
9 | Move the defroster and/or the vent valve to the HEATER mode. Is the defroster airflow correct? | -- | Go to Step 10 | Go to Step 18 | ||||||||||
10 |
Does the airflow change with different blower speeds? | -- | Go to Step 9 | Go to Step 11 | ||||||||||
11 |
Is the heater output temperature correct? | -- | Go to Step 6 | Go to Step 12 | ||||||||||
12 |
Is the temperature valve fully closed? | -- | Go to Step 13 | Go to Step 22 | ||||||||||
13 |
Is the air temperature around both hoses at least at the specified value? | 24°C (85°F) | Go to Step 14 | Go to Step 23 | ||||||||||
14 |
Were the hoses properly installed? | -- | Go to Step 15 | Go to Step 25 | ||||||||||
15 |
Is the air temperature around both hoses at least at the specified value? | 24°C (85°F) | Go to Step 16 | Go to Step 23 | ||||||||||
16 | Replace the heater core. Refer to Heater Core Replacement in Heater and Ventilation -- Non-A/C. Is the repair complete? | -- | Go to Functional Check | -- | ||||||||||
17 |
Is the defroster airflow not present or low? | -- | Go to Step 18 | Go to Step 10 | ||||||||||
18 | Does the airflow change with different blower speeds? | -- | Go to Step 19 | Go to Step 11 | ||||||||||
19 | Inspect for airflow obstructions at the blower inlet and plenum. Did you find and correct a condition? | -- | Go to Functional Check | Go to Step 20 | ||||||||||
20 |
Is a change in the airflow audible? | -- | Go to Step 21 | Go to Step 26 | ||||||||||
21 | Check for an airflow obstruction between the blower and the system outlets. Is the repair complete? | -- | Go to Functional Check | -- | ||||||||||
22 |
Did you find and correct a condition? | -- | Go to Functional Check | -- | ||||||||||
23 | Check the thermostat for proper installation and seating. Is the thermostat properly installed and seated? | -- | Go to Step 27 | Go to Step 24 | ||||||||||
24 | Reinstall the thermostat. Is the repair complete? | -- | Go to Step 13 | -- | ||||||||||
25 | Properly reinstall the hoses. Is the repair complete? | -- | Go to Step 13 | -- | ||||||||||
26 | Inspect the following components:
Is the repair complete? | -- | Go to Functional Check | -- | ||||||||||
27 | Replace the thermostat. Is the repair complete? | -- | Go to Functional Check | -- |