Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the power door system diagnostic system check? | -- | Go to Step 2 | |
2 | Operate the window from both the master (LF) and the RF power window switch. Does the window operate from both the master (LF) window switch and the RF switch? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Does the window operate from the master window switch? | -- | Go to Step 4 | Go to Step 5 |
4 | Test the ground circuit of the RF window switch for an open. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 13 |
5 | Does the window operate from the RF power window switch? | -- | Go to Step 11 | Go to Step 6 |
6 | Connect a test lamp between the RAP2 relay output circuit and ground at the RF switch. Does the test lamp illuminate? | -- | Go to Step 8 | Go to Step 7 |
7 | Test the RAP2 relay output circuit for an open or short to ground. Did you find and correct the condition? | -- | Go to Step 17 | Go to 625378 |
8 |
Does the test lamp illuminate? | -- | Go to Step 10 | Go to Step 9 |
9 | Test the RF power window motor feed circuits for an open. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 13 |
10 | Replace the power window motor. Did you complete the replacement? | -- | Go to Step 17 | -- |
11 |
Does the test lamp illuminate? | -- | Go to Step 12 | Go to Step 14 |
12 |
Does the test lamp illuminate? | -- | Go to Step 13 | Go to Step 15 |
13 | Replace the power RF window switch. Did you complete the replacement? | -- | Go to Step 17 | -- |
14 | Test the RF window down circuit from the master switch for an open. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 16 |
15 | Test the RF window up circuit from the master switch for an open. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 16 |
16 | Replace the master window switch. Did you complete the replacement? | -- | Go to Step 17 | -- |
17 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |