The air temperature actuator is an electronic device that incorporates a stepper motor and feedback potentiometer. The HVAC control module determines the position of the air temperature actuator based on the voltage from the potentiometer. When a change in air temperature is required (greater than 4 counts) the HVAC control module will drive the air temperature actuator in the appropriate direction to achieve the desired setting while comparing the actual position to the commanded position. If the actual value differs from the commanded value by 4 or more counts, the actuator is considered stalled and the DTC will set.
• | The ignition is ON. |
• | Ignition voltage is between 9-16 volts. |
• | An actuator positional change is attempted. |
The actual air mix door position differs from the commanded air mix door position by 4 counts or more.
The actuator is considered stalled and the HVAC control module will command the actuator to stop rotation (2.5 V).
• | If the HVAC control no longer detects a failure, then the DTC will become history. |
• | The history DTC will clear after 50 ignition cycles without a failure. |
• | The DTC can be cleared with a scan tool. |
• | A dead zone exists in a range 10 counts above or below the mix door max or mix door min positions. When the air mix door actual data parameter is within the dead zone, the DTC will not set. If the air mix door commanded data parameter differs from the air mix door actual data parameter by 4 counts or more outside the dead zone, the DTC will set. |
• | A damaged or broken air temperature door and or actuator can cause this DTC to set. |
• | If condition not present refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
Step | Action | Values | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics | ||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Does the scan tool indicate that DTC B0248, B0268, B0429 and B03531 set along with B0408? | -- | Go to Step 3 | |||||||
3 |
Does the scan tool indicate that the Air Mix Door Commanded data parameter is within the specified value of the Air Mix Door Actual data parameter? | 0-3 Counts | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 4 | ||||||
4 |
Does the Air Mix Door Actual data parameter change at all? | -- | Go to Step 9 | Go to Step 5 | ||||||
5 | Test the ignition 3 voltage circuit of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 6 | ||||||
6 | Test the 5 volt reference circuit of the air temperature actuator for an open, high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 7 | ||||||
7 | Test the air temperature door control circuit of the air temperature actuator for an open, high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 8 | ||||||
8 | Test the air temperature actuator ground for open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 9 | ||||||
9 |
Important:: The air temperature actuator connector and the HVAC control module connector must be connected to correctly perform test.
Does the air temperature actuator drive shaft rotate and do the counts change? | -- | Go to Step 12 | Go to Step 10 | ||||||
10 | Inspect the air temperature door and the air temperature actuator for the following:
Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 11 | ||||||
11 | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 13 | ||||||
12 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 14 | ||||||
13 |
Important:: Perform the recalibration procedure for the air temperature actuator. Replace the air temperature actuator. Refer to Air Temperature Actuator Replacement . Did you complete the replacement? | -- | Go to Step 15 | -- | ||||||
14 |
Important:: Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 15 | -- | ||||||
15 |
Does the DTC reset? | -- | Go to Step 2 | System OK |