Caution: Refer to Brake Dust Caution in the Preface section.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nut to 3.5 N·m (31 lb in).
Caution: Refer to Brake Dust Caution in the Preface section.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolt to 3 N·m (25 lb in).
Tighten
Tighten the bolt to 61 N·m (45 lb ft).
Caution: Refer to Brake Dust Caution in the Preface section.
5.1. | Compress the spring (3) by pushing towards the lever (1). |
5.2. | Depress the locking tabs. |
5.3. | Pull the cable housing out of the backing plate (4). |
5.4. | Remove the cable (2) through the slot in the backing plate. |
10.1. | Compress the spring (3) by pushing towards the lever (1). |
10.2. | Route the cable (2) through the slot in the backing plate. |
10.3. | Push the cable housing into the backing plate (4) until the locking tabs snap into place. |