J 43181 Heater Line Quick Connect Release Tool
Important: After removing the turbocharger air ducts, cover the openings with tape to prevent entry of objects.
Important: Do not use a screwdriver or other tool to pry the hose loose. The hose can be torn or damage. Loosen the hose by twisting.
• | The generator does not require removal. |
• | The drive belt tensioner does not require removal. |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nut to 9 N·m (80 lb in).
Tighten
Tighten the bolts to 21 N·m (15 lb ft).
Tighten
Tighten the bolt to 21 N·m (15 lb ft).
Tighten
Tighten the bolt to 21 N·m (15 lb ft).
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
Tighten
Tighten the bolt to 43 N·m (32 lb ft).
Tighten
Tighten the bolts to 35 N·m (26 lb ft).
Tighten
Tighten the nut to 9 N·m (80 lb in).
Tighten
Tighten the clamps to 6 N·m (53 lb in).
Important: The outlet duct must be fully seated against the MAT/IAT sensor with the edge of the seal in the vertical position.
Tighten
Tighten the clamps to 6 N·m (53 lb in).
Tighten
Tighten the clamp to 6 N·m (53 lb in).