GM Service Manual Online
For 1990-2009 cars only

Circuit Description

The engine control module (ECM) uses an exhaust gas recirculation (EGR) vacuum vent solenoid and an EGR valve vacuum control solenoid to control the position of the EGR valve. When the EGR valve is desired to open, the EGR vacuum vent solenoid is commanded open and the EGR valve vacuum control solenoid is commanded open. This will allow vacuum from the vacuum pump to open the EGR valve. When the EGR valve is desired closed, the EGR valve vacuum control solenoid is commanded closed and the EGR vacuum vent solenoid is commanded closed. When the EGR vacuum vent solenoid is commanded closed, the EGR vacuum control system is vented to atmosphere which causes the EGR valve to close very fast. The EGR vacuum vent solenoid is supplied 12 volts by the ignition 1 voltage circuit. The EGR vacuum vent solenoid is controlled through the EGR vacuum vent solenoid control circuit by the ECM. If the ECM detects a high voltage condition on the EGR vacuum vent solenoid control circuit, DTC P2145 sets.

Conditions for Running the DTC

    • The ignition is ON for more than 0.5 seconds.
    • The EGR vacuum vent solenoid is commanded ON.
    • The Ignition 1 Signal parameter is between 11-18 volts.

Conditions for Setting the DTC

    • A high voltage condition on the control circuit of the EGR vacuum vent solenoid is detected by the ECM when the EGR vacuum vent solenoid is commanded ON.
    • The above conditions are met for more than 4 seconds.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Step

Action

Values

Yes

No

Schematic Reference: Engine Controls Schematics

Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check-Engine Controls?

--

Go to Step 2

Go to Diagnostic System Check - Engine Controls

2

  1. Turn the ignition ON, with the engine OFF.
  2. Command the EGR Vent ON and OFF with a scan tool.

Does the EGR vacuum vent solenoid click when commanded ON and OFF?

--

Go to Step 3

Go to Step 5

3

  1. Turn OFF the ignition.
  2. Disconnect the ECM harness connector containing the EGR vacuum vent solenoid control circuit.
  3. Connect a DMM between the EGR vacuum vent solenoid control circuit and a good ground.
  4. Set the DMM to the 10 amp scale
  5. Turn ON the ignition with the engine OFF.
  6. Observe the DMM for 2 minutes.

Does the current measure less than the specified value for the entire 2 minutes.

0.75 A

Go to Step 4

Go to Step 9

4

  1. Turn OFF the ignition.
  2. Reconnect the ECM connector.
  3. Observe the Freeze Frame/Failure Records data for this DTC.
  4. Turn OFF the ignition for 30 seconds.
  5. Start the engine.
  6. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 5

Go to Intermittent Conditions

5

  1. Connect a test lamp between the control circuit of the EGR vacuum vent solenoid and the ignition 1 voltage circuit of the EGR vacuum vent solenoid.
  2. Command the EGR Vent ON and OFF with a scan tool.

Does the test lamp turn ON and OFF when commanded with a scan tool?

--

Go to Step 7

Go to Step 6

6

Test the Control circuit of the EGR vacuum vent solenoid for a short to voltage. Refer to Testing for a Short to Voltage and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 11

Go to Step 8

7

Test for an intermittent and for a poor connection at the EGR vacuum vent solenoid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 11

Go to Step 9

8

Test for an intermittent and for a poor connection at the ECM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 11

Go to Step 10

9

Replace the EGR vacuum vent solenoid. Refer to Exhaust Gas Recirculation Valve Vent Solenoid Replacement .

Did you complete the replacement?

--

Go to Step 11

--

10

Replace the ECM. Refer to Engine Control Module Replacement .

Did you complete the replacement?

--

Go to Step 11

--

11

  1. Clear the DTCs with a scan tool.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 12

Go to Step 2

12

Observe the Capture Info with a scan tool.

Are there any DTCs that have not been diagnosed?

--

Go to Diagnostic Trouble Code (DTC) List

System OK