- For the correct governor settings, refer
to
Governor Adjustment Specifications
Adjustments may be necessary if the range falls below 100 kPa
(15 psi) or if the pressure settings are incorrect. Before making any
adjustments, check the governor hoses for restrictions.
Remove the plastic cover from the governor.
- Loosen the jam nut.
- Turn the adjusting screw counterclockwise in order to raise the
pressure setting or clockwise in order to lower the pressure setting.
- Tighten the jam nut after the adjustment.
- Recheck the cut-in and cut-out pressures. Refer to
Governor
- Install the cover on the governor.