Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the voltage measure less than 10 volts? | 10 V | Go to Step 2 | Go to Step 3 |
2 | Locate and repair the open in CKT 2 (RED) between the fusible link and the generator connector, cavity S. Is the repair complete? | -- | System OK | -- |
3 |
Does the voltage measure less than 10 volts? | 10 V | Go to Step 4 | Go to Step 5 |
4 | Locate and repair the open in CKT 2 (RED) between the fusible link and the generator BAT terminal. Is the repair complete? | -- | System OK | -- |
5 |
Does the voltage measure less than 10 volts? | 10 V | Go to Step 6 | Go to Step 7 |
6 | Locate and repair the open in CKT 39 (PNK) between the IP fuse block and the generator. Is the repair complete? | -- | System OK | -- |
7 |
Does the voltage measure 13-16 volts? | 13-16 V | Go to Battery Not Operating Properly . | Go to Step 8 |
8 |
Is the repair complete? | -- | System OK | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the voltage measure less than 10 volts? | 10 V | Go to Step 2 | Go to Step 3 |
2 | Repair or replace the CKT 2 (RED) wire between the fusible link and the generator connector. Is the repair complete? | -- | System OK | -- |
3 |
Does the voltage measure less than 10 volts? | 10 V | Go to Step 4 | Go to Step 5 |
4 | Repair or replace the CKT 2 (RED) wire between the fusible link and the generator. Is the repair complete? | -- | System OK | -- |
5 |
Does the voltage measure less than 10 volts? | 10 V | Go to Step 6 | Go to Step 7 |
6 | Locate and repair the open in CKT 39 (PNK) between the IP fuse block and the generator connector. Is the repair complete? | -- | System OK | -- |
7 |
Does the voltage measure between 13-16 volts? | 13-16 V | Go to Battery Not Operating Properly . | Go to Step 8 |
8 |
Is the repair complete? | -- | System OK | -- |