Caution: Batteries produce explosive gases. Batteries contain corrosive acid.
Batteries supply levels of electrical current high enough to cause burns.
Therefore, in order to reduce the risk of personal injury while working
near a battery, observe the following guidelines:
• Always shield your eyes. • Avoid leaning over the battery whenever possible. • Do not expose the battery to open flames or sparks. • Do not allow battery acid to contact the eyes or the skin. - Flush any contacted areas with water immediately and thoroughly. - Get medical help.
Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Caution: Batteries produce explosive gases. Batteries contain corrosive acid.
Batteries supply levels of electrical current high enough to cause burns.
Therefore, in order to reduce the risk of personal injury while working
near a battery, observe the following guidelines:
| ||||||||||||||||
1 |
Does the negative (-) connector rotate? | -- | Go to Step 2 | Go to Step 3 | ||||||||||||
2 | Use a torque wrench in order to verify the torque to loosen the negative (-) battery terminal bolt. Is the torque above the specified value? | 10 N·m (84 lb in) | Go to Step 4 | Go to Step 3 | ||||||||||||
3 |
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components. Disconnect the negative (-) battery cable. Is the cable disconnected? | -- | Go to Step 5 | -- | ||||||||||||
4 | Ensure the negative (-) battery cable is disconnected. Inspect for the following conditions and repair as needed:
Is the repair complete? | -- | Go to Step 5 | -- | ||||||||||||
5 | Rotate the positive (+) battery cable connector clockwise with light finger pressure. Does the positive (+) connector rotate? | -- | Go to Step 6 | Go to Step 7 | ||||||||||||
6 | Use a torque wrench in order to verify the torque to loosen the positive (+) battery terminal bolt. Is the torque above the specified value? | 10 N·m (84 lb in) | Go to Step 8 | Go to Step 7 | ||||||||||||
7 | Disconnect the positive (+) battery cable. Is the cable disconnected? | -- | Go to Step 9 | -- | ||||||||||||
8 | Ensure the positive (+) battery cable is disconnected. Inspect for the following conditions and repair as needed:
Is the repair complete? | -- | Go to Step 9 | -- | ||||||||||||
9 |
Are the metal connecting parts clean and in good condition? | -- | Go to Step 10 | -- | ||||||||||||
10 |
Is the cable bolt properly tightened? | 12 N·m (106 lb in) | Go to Step 11 | -- | ||||||||||||
11 |
Is the cable bolt properly tightened? | 12 N·m (106 lb in) | Battery Terminals OK | -- |