Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Cooling Schematics Connector End View Reference: Cooling System Connector End Views DEFINITION: The starter generator control module (SGCM) coolant fan motor does not operate. | |||
1 | Did you perform the Diagnostic System Check - Engine Cooling? | Go to Step 2 | |
2 |
Does the SGCM coolant fan turn ON and OFF with each command? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 7 |
4 | Connect a 20 A fused jumper wire between the battery positive voltage circuit and the SGCM coolant fan motor supply voltage circuit at the coolant fan relay. Does the coolant fan operate? | Go to Step 10 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 8 |
6 | Probe the harness connector of the SGCM coolant fan motor with a test lamp connected between the SGCM coolant fan motor supply voltage circuit and the ground circuit of the coolant fan motor. Does the test lamp illuminate? | Go to Step 11 | Go to Step 9 |
7 | Repair the battery positive circuit of the SGCM coolant fan relay. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 14 | -- |
8 | Repair the supply voltage circuit of the SGCM coolant fan motor. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 14 | -- |
9 | Repair the ground circuit of the SGCM coolant fan motor. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 14 | -- |
10 | Inspect for poor connections at the SGCM coolant fan relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 12 |
11 | Inspect for poor connections at the harness connector of the SGCM coolant fan motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 13 |
12 | Replace the SGCM coolant fan relay. Did you complete the repair? | Go to Step 14 | -- |
13 | Replace the SGCM coolant fan motor. Refer to Generator Control Module Coolant Fan Motor Replacement . Did you complete the repair? | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |