Important:
• | Do not use a chemical flush. |
• | Store used coolant in the proper manner, such as in a used engine coolant holding tank. Do not pour used coolant down a drain. Ethylene glycol antifreeze is a very toxic chemical. Do not dispose of coolant into the sewer system or ground water. This is illegal and ecologically unsound. |
• | Various methods and equipment can be used to flush the cooling system. If special equipment is used (such as a back flusher) follow the manufacturer's instructions. |
4.1. | Install the scan tool. |
4.2. | Turn the ignition ON with the engine OFF. |
4.3. | With the scan tool set to Powertrain, Alternative Fuels, Special Functions, SGCM Output Controls, command the GCM pump speed ON for 1 minute. |
4.4. | Turn the ignition OFF. |
Notice: The procedure below must be followed. Improper coolant level could result in a low or high coolant level condition, causing starter/generator control module damage.