Table 1: | BCM Scan Tool Data List |
Table 2: | HVAC Control Module Scan Tool Data List |
Table 3: | PCM Scan Tool Data List |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
Left Solar Sensor | Data | Counts | Varies |
Right Solar Sensor | Data | Counts | Varies |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C Switch | Input/Output | On, Off | Off |
AC Permission | Input/Output | Withheld, Granted | Varies |
Air Inlet Door Actual | Door Positions | Counts | Varies |
Air Inlet Door Commanded | Door Positions | Counts | Varies |
Air Inlet Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
Air Mix Door Left Commanded | Door Positions | Counts | Varies |
Air Mix Door Right Commanded | Door Positions | Counts | Varies |
Auto Switch | Input/Output | On, Off | Off |
Battery Voltage | Input/Output | Volts | 13.5-14.5 V |
Blower Motor PWM Speed | Input/Output | Percent | 12-114% |
Coolant Pump | Input/Output | ON/ OFF | OFF |
Dim Level Requested | Sensor Data | Percent | Varies |
DTM Difference Minimum | Sensor Data | Counts | 2 Counts |
Engine Coolant Temp | Sensor Data | °C/°F | Varies |
Engine Request | Input/Output | Received/ Not Received | Not Received |
Engine Request Priority | Input/Output | Priority 1/ Priority 2 | Priority 1 |
Fan Down Button | Input/Output | On, Off | Off |
Fan Up Button | Input/Output | On, Off | Off |
Front Defrost Switch | Input/Output | On, Off | Off |
Ign. Since Current DTC | Input/Output | Numeric | 0 |
Inside Air Temp. | Sensor Data | °C/°F | Varies |
Inside Air Temp. Fan | Sensor Data | On, Off | On |
Left Mix Door Actual | Door Positions | Counts | Varies |
Left Mix Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
Left Temp. Setting | Input/Output | °C/°F | Varies |
LH AC Duct Actual | Sensor Data | Counts | Varies |
LH AC Duct Desired | Sensor Data | Counts | Varies |
LH Heater Duct Actual | Sensor Data | Counts | Varies |
LH Heater Duct Desired | Sensor Data | Counts | Varies |
Mode Select Position | Door Positions | Off, Auto, Defrost, Heater, Htr/Def, Bi-level, Panel | Varies |
Mode Door Actual | Door Positions | Counts | Varies |
Mode Dr. Motor Command | Door Positions | Counts | Varies |
Mode Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
Mode Switch | Input/Output | On, Off | Off |
Off Switch | Input/Output | On, Off | Off |
Outside Air Temp. Filtered | Input/Output | °C/°F | 22-27°C (70-80°F) |
Outside Air Temp. Raw | Input/Output | °C/°F | Varies |
Pressure Cycle Switch | Input/Output | Low Pressure, Normal | Varies |
Rear Defrost Switch | Input/Output | On, Off | Off |
Recirculate Switch | Input/Output | On, Off | Off |
RH AC Duct Actual | Sensor Data | Counts | Varies |
RH AC Duct Desired | Sensor Data | Counts | Varies |
RH Heater Duct Actual | Sensor Data | Counts | Varies |
RH Heater Duct Desired | Sensor Data | Counts | Varies |
Right Mix Door Actual | Door Positions | Counts | Varies |
Right Mix Motor Drive | Door Positions | Stop, Increase, Decrease | Stop |
Right Temp. Setting | Input/Output | °C/°F | Varies |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C Pressure Sensor | Engine Data 2 | kPa, Psi | 629-845 kPa (85-120 psi) |
A/C Pressure Sensor | Engine Data 2 | Volts | Varies |
A/C Relay Command | Engine Data 2 | On, Off | Varies |
A/C Request Signal | Engine Data 2 | Yes, No | Varies |
ECT Sensor | Engine Data 2 | °C/°F | 92°C (197°F) |
ECT Sensor | Engine Data 2 | Volts | 1.10-1.45 Volts |