Tools Required
• |
J 26568
Coolant and Battery Tester |
Draining Procedure
Caution: To avoid being burned, do not remove the starter/generator control
module (SGCM) cap while the SGCM is hot. The cooling system will release scalding
fluid and steam under pressure if the SGCM cap is removed while the SGCM is still
hot.
- Follow the steps below in order to remove the generator control module (GCM) tank
fill cap.
1.1. | Slowly rotate the cap counterclockwise. |
1.2. | Stop rotating and allow the hissing to stop. |
1.3. | After all the hissing stops, continue turning counterclockwise in order to remove the cap. |
- Remove the grille from the vehicle. Refer to
Grille Replacement
.
- Place a drain pan under the GCM radiator.
- Remove the GCM coolant pump outlet hose from the radiator. Refer to
Generator Control Module Coolant Pipe Quick Connect Fitting Replacement
.
- Drain the cooling system.
- Inspect the coolant.
- Follow the appropriate procedure based on the condition of the coolant.
• | Normal in appearance--Follow the filling procedure. |
Filling Procedure
- Install the GCM coolant pump outlet hose to the radiator. Refer to
Generator Control Module Coolant Pipe Quick Connect Fitting Replacement
.
Notice: The procedure below must be followed. Improper coolant level could result in
a low or high coolant level condition, causing starter/generator control module damage.
Important: Use a 50/50 mixture of DEX-COOL antifreeze and clean, drinkable water.
Fill the GCM cooling system until the coolant reaches the full cold mark.
- Slowly fill the cooling system with a 50/50 coolant mixture. Refer to
Approximate Fluid Capacities
.
Important: Do not exceed the pressure cap rating.
- Use the
J 24460-01
with the
J 46143
in order to apply pressure to the cooling system.
- To run the GCM coolant pump, perform the following steps:
4.1. | Install the scan tool. |
4.2. | Turn the ignition ON with the engine OFF. |
4.3. | With the scan tool set to Powertrain, Alternative Fuels, Special Functions, SGCM Output Controls, command the GCM pump speed ON for 1 minute. |
4.4. | Turn the ignition OFF. |
- Remove the cooling system pressure tester and adapter from the GCM cooling system.
- Top off the coolant as necessary.
- Repeat step 3 through 7 until the GCM cooling system is at the full cold mark.
Important: Make sure the coolant is flowing.
- Inspect the concentration of the GCM coolant, using the
J 26568
.