GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 782174  Size: SH
  1. Drain the cooling system to a level below the sensor. Refer to Cooling System Draining and Filling .
  2. Disconnect the engine coolant temperature (ECT) sensor electrical connector (5).

  3. Object Number: 246800  Size: SH

    Notice: Use care when handling the coolant sensor. Damage to the coolant sensor will affect the operation of the fuel control system.

  4. Remove the ECT sensor.

Installation Procedure

Notice: Replacement components must be the correct part number for the application. Components requiring the use of the thread locking compound, lubricants, corrosion inhibitors, or sealants are identified in the service procedure. Some replacement components may come with these coatings already applied. Do not use these coatings on components unless specified. These coatings can affect the final torque, which may affect the operation of the component. Use the correct torque specification when installing components in order to avoid damage.

Notice: Use care when handling the coolant sensor. Damage to the coolant sensor will affect the operation of the fuel control system.


    Object Number: 246800  Size: SH
  1. If installing the old sensor, coat the threads with sealant GM P/N 12346004 (Canadian P/N  10953480), or equivalent.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the ECT sensor.
  4. Tighten
    Tighten the sensor to 20 N·m (15 lb ft).


    Object Number: 782174  Size: SH
  5. Connect the ECT sensor electrical connector (5).
  6. Fill the cooling system, if necessary. Refer to Cooling System Draining and Filling .