Scan Tool Data Definitions Non HP2
Ignition 1 Signal: The scan tool displays the current voltage
at the battery.
GEN L--Terminal Signal Command: The scan tool displays
OK/No Output. The scan tool displays OK until malfunction is detected on the generator
L terminal circuit, then it reads No Output.
GEN F--Terminal Signal: The scan tool displays 0-100%.
The scan tool displays 0-5% until the engine is running, then the
percentage value varies depending on electrical loads.
Scan Tool Data Definitions HP2
Aux. Power Outlets Status: The scan tool displays the actual
of the auxiliary power outlet modes. Off, normal and continuous are the three available
power modes.
Aux. Power Outlets Switch: The scan tool displays the actual
switch position of pressed or released.
Aux. Power Outlets Target Idle Speed: The scan tool
displays the actual target idle speed needed for proper APO operation.