Table 1: Torque Converter End Play Specifications
Table 2: Torque Converter Wear Limits Specifications

Torque Converter End Play Specifications

Torque Converter Condition

Maximum Allowable End Play

New

0.762 mm (0.030 inch)

Used

1.015 mm (0.040 inch)

Torque Converter Wear Limits Specifications

Measurement

Allowable Wear Limits

Minimum OD of Hub - Bushing Wear Area

58.250 mm (2.2933 inch)

Minimum Distance Between Hub Flats

51.691 mm (2.0351 inch)

Minimum OD of Cover Pilot

43.16 mm (1.699 inch)