J 36608 Fuel Sender Tool
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components.
Important: Do not damage the rubber insulator or the strainer.
Notice: Do not fold or twist the strainer when installing the sending unit. This action restricts fuel flow.
8.1. | Turn ON the ignition switch for 2 seconds. The scan tool can be used to activate the fuel pump to check for fuel system leaks. |
8.2. | Turn OFF the ignition switch for 10 seconds. |
8.3. | Again, turn the ignition switch to the ON position. |
8.4. | Check for fuel leaks. |