• | J 39500-B R-134a A/C Refrigerant Recovery, Recycling and Recharging System (ACR4) |
• | J 5403 Snap Ring Pliers |
• | J 23128-A Seal Seat Remover and Installer |
• | J 33011 O-Ring Installer |
• | J 34614 Shaft Seal Protector |
• | J 39893 Pressure Testing Connector |
Notice: Seals should not be re-used. Always use a new specification service seal kit. Be sure that the seal to be installed is not scratched or damaged in any way. Make sure that the seal is free of lint and dirt that could damage the seal surface or prevent sealing.
Notice: Handling and care of the seal protector is important. If the seal protector is nicked or the bottom flared, the new seal may be damaged during installation.
15.1. | Install the J 39893 on the rear head of the compressor. |
15.2. | Connect the gage charging lines and the J 39500-B . |
15.3. | Pressurize the suction and the high-side of the compressor using R-134a Refrigerant. |
15.4. | Temporarily install a M9 x 1.25 threaded nut on the shaft. |
15.5. | With the compressor in a horizontal position, rotate the compressor shaft in the normal direction of rotation several turns by hand. |
15.6. | Leak test the seal area. Correct any leaks found. |
15.7. | Recover the refrigerant. |
15.8. | Remove the shaft nut. |