Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the HVAC Blower Controls System Check been performed? | -- | Go to Step 2 | |
2 |
Does the blower motor run? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the auxiliary blower motor relay, low. Refer to Blower Motor Relay Replacement . Is the repair complete? | -- | -- | |
4 |
Is continuity present? | -- | Go to Step 6 | Go to Step 5 |
5 | Replace the auxiliary HVAC control module. Refer to the following: Is the repair complete? | -- | -- | |
6 |
Is continuity present? | -- | Go to Step 8 | Go to Step 7 |
7 | Replace the auxiliary blower resistor. Refer to Auxiliary Blower Motor Resistor Replacement . Is the repair complete? | -- | -- | |
8 | Connect a J 39200 (volts) between cavity 1 of the high relay socket and ground. Is battery voltage present? | -- | Go to Step 10 | Go to Step 9 |
9 | Locate and repair the open in CKT 542 (RED) between cavity 1 of the auxiliary blower relay, low and splice S401. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
10 | Locate and repair the open in CKT 1926 (DK BLU) between the auxiliary blower motor relay, low and the auxiliary HVAC control modules, front and rear. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |