- Install the auxiliary compressor hose (2).
- Install the auxiliary evaporator hose (1).
- Install the hose clips (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws (4).
Tighten
Tighten the screws to 6 N·m (53 lb in).
- Coat the new O-ring seal (2) for the auxiliary compressor
hose (3) with 525 viscosity refrigerant oil.
- Install the new O-ring seal.
- Connect the auxiliary compressor hose to the auxiliary evaporator (1).
Tighten
Tighten the auxiliary compressor hose to 32 N·m (24 lb ft).
- Coat the new O-ring seal (2) for the auxiliary evaporator
hose (4) with 525 viscosity refrigerant oil.
- Install the new O-ring seal.
- Connect the auxiliary evaporator hose to the auxiliary evaporator.
Tighten
Tighten the auxiliary evaporator hose to 17 N·m (13 lb ft).
- Install the right front wheelhouse. Refer to
Rear Wheel Opening Flare Replacement
.
- Coat the new O-ring seal (5) for the auxiliary compressor
hose (4) with 525 viscosity refrigerant oil.
- Install the new O-ring seal.
- Connect the refrigerant hose assembly (6) to the auxiliary
compressor hose.
Tighten
Tighten the refrigerant hose assembly to 24 N·m (18 lb ft).
- Lower the vehicle.
- Coat the new O-ring seal (2) for the auxiliary evaporator
hose (3) with 525 viscosity refrigerant oil.
- Install the new O-ring seal.
- Connect the auxiliary evaporator tube (1) to the auxiliary
evaporator hose.
Tighten
Tighten the evaporator tube to 24 N·m (18 lb ft).
- Install the air cleaner assembly.
- Charge the system. Refer toRefrigerant Recovery and Recharging
.
- Inspect the system for leaks. Refer to
Leak Testing
.