Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: This diagnostic should only be used if the door locks are operational but do not lock after the last door is closed. | ||||
1 | Has the Power Door Locks System Check been performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair open in CKT 195 (LT BLU) between door lock control module and S431. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 |
Does test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair short to ground in CKT 328 (PPL) between door lock control module and door jamb switches.module and S431. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Connect a test lamp between door lock control module connector cavity F and B+. Does test lamp light? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair short to ground in CKT 1897 (ORN/BLK) between door lock control module and rear door jamb switch.module and S431. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 |
Does the test lamp light? | -- | Go to Step 9 | Go to Step 10 |
9 | Replace the door lock control module. Is the repair complete? | -- | -- | |
10 | Repair the open in CKT 1897 (ORN/BLK) between door lock control module and rear door jamb switch.module and S431. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |