Step

Action

Value(s)

Yes

No

1

Has the HVAC Blower Controls System Check been performed?

--

Go to Step 2

Go to HVAC Blower Controls System Check

2

  1. Remove the blower motor relay high.
  2. Connect a J 39200 between pins C2 and A1 of the blower motor relay high.

Is continuity present?

--

Go to Step 4

Go to Step 3

3

Replace the blower motor relay high. Refer to Blower Motor Relay Replacement .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

4

  1. Connect a jumper wire between the blower motor relay high and pin C2 and B+.
  2. Connect a jumper wire between the blower motor relay high and pin A1 and ground.
  3. Connect a J 39200 between pins A2 and C1 of the blower motor relay high.

Is continuity present?

--

Go to Step 5

Go to Step 3

5

Connect a J 39200 between the blower motor relay high cavity A1 and ground.

Is there continuity?

--

Go to Step 7

Go to Step 6

6

Locate and repair the open in CKT 150 (BLK) between the blower motor relay high and ground G202. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

7

Connect a J 39200 between the blower motor relay high cavity A2 and ground.

Is battery voltage present?

--

Go to Step 9

Go to Step 8

8

Locate and repair the open in CKT 542 (RED) between the underhood block and the blower motor relay high. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

9

  1. Disconnect connector C2 at the HVAC control module.
  2. Connect a J 39200 (continuity) between the HVAC control module connector C2, cavities H and G.
  3. Turn the HVAC control module to the HIGH position.

Is there continuity?

--

Go to Step 10

Go to Step 11

10

Locate and repair the open in CKT 52 (ORN) between the HVAC control module and the blower motor relay high. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

11

Replace the HVAC control module. Refer to Control Assembly Replacement .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--