Step
| Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the HVAC Air Delivery System Check been performed? | -- | Go to Step 2 | |
2 |
Is battery voltage present? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair the open in CKT 141 (BRN) between the IP fuse block and the front mode door motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 | Connect a J 39200 (continuity) between the front temperature door motor connector, cavity 7, and ground. Is continuity present? | -- | Go to Step 6 | Go to Step 5 |
5 | Locate and repair the open in CKT 150 (BLK) between the front temperature door motor and splice S244. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 |
Is the J 39200 response a smooth, variable voltage? | -- | Go to Step 9 | Go to Step 7 |
7 |
Is the J 39200 response a smooth, variable voltage? | -- | Go to Step 8 | Go to Step 10 |
8 | Locate and repair the open or cause of resistance in CKT 454 (WHT) between the HVAC control module and the front temperature door motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
9 | Replace the front temperature door motor. Refer to Temperature Actuator Replacement . Is the repair complete? | -- | -- | |
10 | Replace the HVAC control module. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Has the HVAC Air Delivery System Check been performed? | -- | Go to Step 2 | |||||||||||
2 |
Does the J 39200 indicate a smooth, variable voltage? | -- | Go to Step 3 | Go to Step 10 | ||||||||||
3 |
Is continuity present? | -- | Go to Step 5 | Go to Step 4 | ||||||||||
4 | Locate and repair the open in CKT 454 (WHT) between the auxiliary HVAC control logic module and the auxiliary temperature door motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||||||
5 | Connect a J 39200 (continuity) between cavity 7 of the auxiliary temperature door motor connector and ground. Is continuity present? | -- | Go to Step 7 | Go to Step 6 | ||||||||||
6 | Locate and repair the open in CKT 150 (BLK) between the auxiliary temperature door motor and splice S403. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||||||
7 | Connect a J 39200 (volts) between cavity 10 of the auxiliary temperature door motor connector and ground. Is battery voltage present? | -- | Go to Step 9 | Go to Step 8 | ||||||||||
8 | Locate and repair the open in CKT 341 (BRN) between the auxiliary temperature door motor and splice S400. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||||||
9 | Replace the auxiliary temperature door motor. Refer to Temperature Actuator Replacement - Auxiliary . Is the repair complete? | -- | -- | |||||||||||
10 |
Is voltage present? | -- | Go to Step 12 | Go to Step 11 | ||||||||||
11 | Locate and repair the open in CKT 341 (BRN) between the auxiliary HVAC control logic module and splice S308. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||||||
12 |
Does the J 39200 indicate a smooth, variable voltage | -- | Go to Step 13 | Go to Step 14 | ||||||||||
13 | Replace the auxiliary HVAC control logic module. Is the repair complete? | -- | -- | |||||||||||
14 |
Does the J 39200 indicate a smooth, variable voltage? | -- | Go to Step 16 | Go to Step 15 | ||||||||||
15 | Replace the auxiliary HVAC module that was tested in step 14. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front (front) or Control Assembly Replacement - Auxiliary (rear). Is the repair complete? | -- | -- | |||||||||||
16 | Locate the open or cause of resistance in CKT 920 (DK BLU) between the auxiliary HVAC control logic module and the rear auxiliary HVAC control module and the or CKT 919 (LT BLU) to the front auxiliary HVAC control module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |