Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Did you perform the Backup Lights System Check ?  | --  | Go to Step 2  | Go to Backup Lamp System Check  | ||||
2  | 
 Does the test lamp light?  | --  | Go to Step 3  | Go to Step 4  | ||||
3  | Connect a J 39200 DMM from the switch connector, terminal F (automatic) or terminal A (manual) to ground. Is there continuity?  | --  | Go to Step 5  | Go to Step 6  | ||||
4  | Repair the open in CKT 139 (PNK) between the instrument panel fuse block and the park/neutral position switch (automatic), backup lamp switch (manual). Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | ||||
5  | 
 
 Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | ||||
6  | 
 Did you find and correct a condition?  | --  | Go to Backup Lamp System Check  | Go to Step 7  | ||||
7  | Repair the open in CKT 150 (BLK) between the backup lamps and ground G401. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  |