• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Wait To Start Signal | P0381 | P0381 | P0381 | -- |
Ignition voltage is supplied directly to the wait to start indicator. The engine control module (ECM) controls the lamp by grounding the control circuit via an internal switch called a driver. The primary function of the driver is to supply the ground for the component being controlled. Each driver has a fault line which is monitored by the ECM. When the ECM is commanding a component ON, the voltage of the control circuit should be low, near zero volts. When the ECM is commanding the control circuit to a component OFF, the voltage potential of the circuit should be high, near battery voltage. If the fault detection circuit senses a voltage other than what is expected, the fault line status will change causing the DTC to set.
• | The ignition voltage is greater than 10 volts but less than 16 volts. |
• | The ignition is ON. |
• | The ECM detects that the commanded state of the driver and the actual state of the control circuit do not match. |
• | The condition must be present for a minimum of 5 seconds. |
• | The ECM stores the DTC information in memory. |
• | The ECM records the operating conditions at the time the DTC sets. The ECM displays the failure information in the Failure Records on the scan tool. |
• | The history DTC clears after 40 malfunction free warm-up cycles. |
• | The DTC becomes history when the conditions for setting the DTC are no longer present. |
The wait to start indicator illuminates only with the ignition ON and the engine OFF. The wait to start indicator will not illuminate during post-start glow plug operation. The wait to start indicator will not stay ON for long at higher engine temperatures.
Control Module References for scan tool information
⇒ | If the test lamp remains ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp remains OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit test normal, replace the ECM |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for the ECM or DIC replacement, setup, and programming