Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Heater Blower Controls System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | -- | |
4 | Connect a test lamp between CKT 63 (TAN) cavity at the HVAC Control connector C4 and ground. Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Locate and repair the open in CKT 63 (TAN). Is the repair complete? | -- | -- | |
6 | Replace the HVAC controller. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- |