GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

Did you perform the Power Windows System Check?

--

Go to Step 2

Go to Power Windows System Check

2

  1. Access the left door lock and side window switch.
  2. Turn the ignition switch to the RUN position.
  3. Connect a J 39200 digital multimeter (DMM) to CKT 167 (TAN), terminal D and CKT 166 (LT BLU), terminal B at the left door lock and side window switch connector C2.
  4. Operate the right window at the left door lock and side window switch in the UP/DOWN position.
  5. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 6

Go to Step 3

3

Inspect for a poor connection at the left door lock and side window switch.

Is the connection OK?

--

Go to Step 5

Go to Step 4

4

Repair the connection as necessary.

Is the repair complete?

--

Go to Power Windows System Check

--

5

Replace the left door lock and side window switch. Refer to Front Side Door Window Switch Replacement .

Is the repair complete?

--

Go to Power Windows System Check

--

6

  1. Access the right front side window switch.
  2. Turn the ignition switch to the RUN position.
  3. Connect a J 39200 DMM to CKT 166 (LT BLU), terminal J at the right window switch connector and ground.
  4. Ensure that the right window switch connector remains connected.
  5. Operate the right window at the left door lock and side window switch in the UP position.
  6. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 8

Go to Step 7

7

Locate and repair the open or high resistance in CKT 166 (LT BLU) between the right window switch connector, terminal J and the left door lock and side window switch connector, terminal B.

Is the repair complete?

--

Go to Power Windows System Check

--

8

  1. Connect a J 39200 DMM to CKT 167 (TAN), terminal L at the right window switch connector C1 and ground.
  2. Ensure that the right window switch connector C1 remains connected.
  3. Operate the right window at the left door lock and side window switch in the DOWN position.
  4. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 10

Go to Step 9

9

Locate and repair the open or high resistance in CKT 167 (TAN) between the right window switch connector, terminal L and the left door lock and side window switch connector, terminal D.

Is the repair complete?

--

Go to Power Windows System Check

--

10

  1. Connect a J 39200 DMM to CKT 666 (DK BLU), terminal G and CKT 667 (BRN), terminal K at the right front window switch connector C1.
  2. Operate the right window at the left door lock and side window switch in the DOWN position.
  3. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 14

Go to Step 11

11

Inspect for a poor connection at the right front door lock and side window switch.

Is the connection OK?

--

Go to Step 13

Go to Step 12

12

Repair the connection as necessary.

Is the repair complete?

--

Go to Power Windows System Check

--

13

Replace the right front door lock and side window switch. Refer to Front Side Door Window Switch Replacement .

Is the repair complete?

--

Go to Power Windows System Check

--

14

  1. Turn the ignition switch to the RUN position.
  2. Place the side window lockout switch in the NORMAL (UNLOCKED) position.
  3. Connect a J 39200 DMM to CKT 1001 (DK GRN), terminal F at the right front window switch connector C1 and ground.
  4. Ensure that the connector C1 remains connected.
  5. Test for voltage.

Is Ignition voltage present?

IGN+

Go to Step 16

Go to Step 15

15

Locate and repair the open or high resistance between CKT 1307 (DK BLU) at S306 and CKT 1001 (DK GRN), terminal F at the right front window switch connector.

Is the repair complete?

--

Go to Power Windows System Check

--

16

  1. Connect a J 39200 DMM to CKT 666 (DK BLU), terminal B at the right front window regulator motor connector C1 and CKT 667 (BRN), terminal K at the right front window switch connector C1.
  2. Operate the right window switch in the UP position.
  3. Test for voltage.

Is Ignition voltage present?

IGN+

Go to Step 18

Go to Step 17

17

Locate and repair the open or high resistance at CKT 666 (DK BLU) between terminal B at the right front window regulator motor connector and terminal G at the right front window switch connector C1.

Is the repair complete?

--

Go to Power Windows System Check

--

18

  1. Connect a J 39200 DMM to CKT 666 (DK BLU), terminal B and CKT 667 (BRN), terminal A at the right front window regulator motor connector.
  2. Operate the right window switch in the DOWN position.
  3. Test for voltage.

Is Ignition voltage present?

IGN+

Go to Step 20

Go to Step 19

19

Locate and repair the open or high resistance at CKT 667 (BRN) between terminal A at the right front window regulator motor connector and terminal K at the right front window switch connector C1.

Is the repair complete?

--

Go to Power Windows System Check

--

20

Inspect for a poor connection at the right front side window regulator motor.

Is the connection OK?

--

Go to Step 22

Go to Step 21

21

Repair the connection as necessary.

Is the repair complete?

--

Go to Power Windows System Check

--

22

Replace the right front side window regulator motor. Refer to Power Window Motor Replacement .

Is the repair complete?

--

Go to Power Windows System Check

--