Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Charging System Check? | -- | Go to Charging System Check | |||||
2 | Using the scan tool, inspect for any DTCs. Are any DTCs present? | -- | Go to the Appropriate DTC | |||||
3 |
Do all of the indicator bulbs turn ON and OFF properly? | -- | Go to Instrument Cluster System Check in Instrument Panel, Gauges and Console | |||||
4 | Disconnect the generator connector. Is the battery indicator still ON? | -- | ||||||
5 |
Is continuity present? | -- | ||||||
6 | Repair the short to ground. Is the repair complete? | -- | Go to Charging System Check | -- | ||||
7 | Using the J 39200 DMM, measure the voltage at the battery stud on the generator. Is the voltage within the specified range? | 9-16 V | ||||||
8 | Repair or replace the generator. Is the repair complete? | -- | Go to Charging System Check | -- | ||||
9 | Repair the open in CKT 2 (RED). Is the repair complete? | -- | Go to Charging System Check | -- |