Important: Prior to replacement of the combination valve, note the identification code on the valve. It is necessary to have the proper code when replacing the valve.
Important: Do not reuse the transfer tubes (13). Always install new transfer tubes with a new combination valve.
Important: Verify that the replacement combination valve has the same pin punched identification code as the code found on the old part.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten bolts first to 8 N·m (6 lb ft), then to 16 N·m (12
lb ft).
Tighten
Tighten brake pipe fittings to 17 N·m (13 lb ft).
Important: Verify that the combination valve metering rod is depressed during bleeding.