Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 | Did you perform the BCM Diagnostic System Check? | -- | Go to Step 3 | Go to Diagnostic System Check - Body Control System in Body Control System |
3 | Did you perform the Lift Window Release System Check? | -- | Go to Step 4 | Go to Liftgate Window Release System Check in Body Rear End |
4 |
Does the REAR GATE/DOOR output indicate CLOSED with the endgate/liftgate open? | -- | Go to Step 5 | Go to Step 12 |
5 |
Does the REAR GATE/DOOR output indicate CLOSED with the endgate/liftgate open? | -- | Go to Step 6 | Go to Instrument Cluster System Check or Diagnostic System Check - Body Control System in Body Control System |
6 |
Is battery voltage present? | -- | Go to Step 7 | Go to Step 13 |
7 |
Is the GATE AJAR indicator on the IP illuminated? | -- | Go to Step 8 | Go to Step 13 |
8 |
Is the GATE AJAR indicator on the IP illuminated? | -- | Go to Step 14 | Go to Step 9 |
9 | Using the J 35616-A , jumper the gate ajar switch connector terminal B to ground. Is the GATE AJAR indicator on the IP illuminated? | -- | Go to Step 10 | Go to Step 11 |
10 | Locate and repair the open or the high resistance in CKT 1350 between the gate ajar switch terminal D and G420 or G450. Refer to Wiring Repairs Is the repair complete? | -- | -- | |
11 | Locate and repair the open or the high resistance in CKT 1303 between the gate ajar switch terminal B and BCM connector C2 terminal B10. Is the repair complete? | -- | -- | |
12 | Replace the instrument cluster. Refer to Instrument Cluster Replacement Is the repair complete? | -- | -- | |
13 |
Is the repair complete? | -- | -- | |
14 | Replace the gate ajar switch. Is the repair complete? | -- | -- |