Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the HVAC system operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify that the blower motor low speed is inoperative. Does the blower motor operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open in CKT 64 (BRN) between the blower motor resistor and S215. Is the repair complete? | -- | Go to Step 6 | -- |
5 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the replacement complete? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |