Did you review the HVAC system operation and perform the necessary inspections?

--

Go to Step 2

Go to Symptoms

2

Verify that the blower motor is always on.

Does the blower motor operate normally?

--

Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems

Go to Step  3

3

Disconnect the blower motor relay.

Does the blower motor stop running?

--

Go to Step 5

Go to Step 4

4

Repair the short to the voltage in CKT  65 (PPL) wire.

Is the repair complete?

--

Go to Step  10

--

5

  1. Turn the blower switch to the LOW position.
  2. Connect a test lamp between CKT 52 (ORN) wire and ground.

Does the test lamp light?

--

Go to Step  6

Go to Step  9

6

Inspect for a short to voltage in CKT 52 (ORN) wire.

Is the circuit OK?

--

Go to Step  8

Go to Step  7

7

Repair the short to voltage in CKT 52 (ORN) wire.

Is the repair complete?

--

Go to Step  10

--

8

Replace the heater and A/C controller. Refer to Control Assembly Replacement .

Is the replacement complete?

--

Go to Step  10

--

9

Replace the blower motor relay.

Is the replacement complete?

--

Go to Step  10

--

10

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step  3