Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test light? | -- | Go to Step 3 | Go to Step 2 |
2 | Locate and Repair the open BLK (1350) wire between component and ground. Is the action complete? | -- | System OK | -- |
3 | Connect a self-powered test lamp from terminal B to ground at the Load Leveling Air Direction Valve. Does the test light? | -- | Go to Step 4 | Go to Step 2 |
4 |
Does the Load Leveling Pump run? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the Load Leveling Inflator Switch. Is the action complete? | -- | System OK | -- |
6 |
Does the Load Leveling Pump run? | -- | Go to Step 8 | Go to Step 7 |
7 | Locate and Repair the open YEL (321) wire between the Load Leveling Timer Relay and Splice S472. Is the action complete? | -- | System OK | -- |
8 |
Does the test lamp light? | -- | Go to Step 12 | Go to Step 9 |
9 |
Does the test lamp light? | -- | Go to Step 10 | Go to Step 11 |
10 | Locate and Repair the open DK BLU (1249) wire. Is the action complete? | -- | System OK | -- |
11 | Replace the Load Leveling Timer Relay. Is the action complete? | -- | System OK | -- |
12 | Using a DMM, (J39200), measure the resistance of the Load Leveling Air Direction Valve. Is the resistance within the value indicated? | 20 - 100 ohms | Go to Step 14 | Go to Step 13 |
13 | Replace the Load Leveling Air Direction Valve. Is the action complete? | -- | System OK | -- |
14 |
Does the test lamp light? | -- | Go to Step 15 | Go to Step 11 |
15 | Locate and Repair the PPL (1267) wire for a short to ground. Is the action complete? | -- | System OK | -- |