Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the Load Leveling Pump stop running? | -- | Go to Step 2 | Go to Step 7 |
2 | Connect a self-powered test lamp from terminal F, BLK (1250) at the Load Leveling Timer Relay to ground. Does the test lamp light? | -- | Go to Step 3 | Go to Step 6 |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 5 |
4 | Locate and Repair the BLK (1250) wire for a shore to ground Is the action complete? | -- | System OK | -- |
5 | Replace the Load Leveling Air Inflator Switch. Is the action complete? | -- | System OK | -- |
6 | Replace the Load Leveling Timer Relay. Is the action complete? | -- | System OK | -- |
7 | Disconnect the Load Leveling Height Sensor. Does the Load Leveling Pump stop running? | -- | Go to Step 8 | Go to Step 9 |
8 | Replace the Load Leveling Height Sensor. Is the action complete? | -- | System OK | -- |
9 |
Does the test lamp light? | -- | Go to Step 10 | Go to Step 11 |
10 | Locate and Repair the YEL (321) wire for a short to ground. Is the action complete? | -- | System OK | -- |
11 | Replace the Load Leveling Pump. Is the action complete? | -- | System OK | -- |