Caution: Wear safety glasses in order to avoid eye damage.
1.1. | Install the bypass valve into the oil gallery bore until slightly below flush with the surface of the block. |
1.2. | Using a pointed punch, stake the block area around the bypass valve. |
Stake in three locations 120 degrees apart.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the oil filter adapter bolts to 21 N·m (15 lb ft).