Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the DLC System Check performed? | -- | Go to Step 2 | |
2 | Was the SIR Diagnostic System Check performed? | -- | Go to Step 3 | Go to SIR Diagnostic System Check in SIR |
3 | Inspect for proper connection of the scan tool to the data link connector at terminal 9. Is the connection good? | -- | Go to Step 4 | Go to Step 14 |
4 |
Is the connection good? | -- | Go to Step 5 | Go to Step 14 |
5 |
Is the resistance greater than the specified value? | 0.5 ohms | Go to Step 6 | Go to Step 8 |
6 | Connect a DMM between SDM terminal 5 and DLC terminal 9. Is the resistance less than the specified value? | 3 ohms | Go to Step 15 | Go to Step 10 |
7 |
Is the voltage within the specified range? | 0-5 V | Go to Step 9 | Go to Step 11 |
8 | Repair the short to ground in CKT 800. Is the repair complete? | -- | Go to SIR Diagnostic System Check in SIR | -- |
9 |
Is the repair complete? | -- | Go to SIR Diagnostic System Check in SIR | -- |
10 | Repair the open in CKT 800. Is the repair complete? | -- | Go to SIR Diagnostic System Check in SIR | -- |
11 | Disconnect the VIU. Is the voltage within the specified range? | 0-5 V | Go to Step 12 | Go to Step 13 |
12 | Replace the VIU. Is the repair complete? | -- | Go to SIR Diagnostic System Check in SIR | -- |
13 |
Is the repair complete? | -- | Go to SIR Diagnostic System Check in SIR | -- |
14 | Repair the connection as needed. Is the repair complete? | -- | Go to SIR Diagnostic System Check in SIR | -- |
15 |
Is the resistance less than the specified value? | 3 ohms | Go to Step 7 | Go to Step 10 |