Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |||||
2 |
Are the temperatures approximately equal or within 25°? | 87°C (190°F) | Go to Step 3 | Go to Step 6 | ||||
3 | Read the monitored coolant temperature from the scan tool. Is the monitored coolant temperature reading within the specified range? | 38-127°C 100-260°F) | Go to Step 4 | Go to Step 5 | ||||
4 | Compare the monitored coolant temperature with the displayed coolant temperature. Are the temperatures approximately equal or within 11°C (25°F)? | -- | Go to Step 5 | Go to Step 6 | ||||
5 |
Is the gauge reading correct? | -- | Go to Powertrain On Board Diagnostic (OBD) System Check in Engine Controls - 2.2L Go to Powertrain On Board Diagnostic (OBD) System Check in Engine Controls - 4.3L | Go to Step 6 | ||||
6 | Replace the IP cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | -- |