Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The lift window release will not activate the release lift window. The lock cylinder switch operates properly. | ||||
1 | Did you perform the Lift Window Release System Check? | -- | Go to Step 2 | |
2 |
Did the liftglass release operate? | -- | Go to Step 10 | Go to Step 3 |
3 |
Did the liftglass release operate? | -- | Go to Step 5 | Go to Step 4 |
4 | Locate and repair an open in CKT 56 (BLK/WHT). Is the repair complete? | -- | -- | |
5 | Test the continuity between liftglass relay terminal 1 and terminal 2. Is continuity present? | -- | Go to Step 7 | Go to Step 6 |
6 | Replace the liftglass relay. Is the repair complete? | -- | -- | |
7 |
Did the liftglass release operate? | -- | Go to Step 9 | Go to Step 8 |
8 | Locate and repair an open in CKT 1344 (LT BLU). Is the repair complete? | -- | -- | |
9 | Replace the BCM. Is the repair complete? | -- | -- | |
10 | Backprobe a fused jumper wire between terminal D and terminal E of the window release switch. Did the liftglass release operate? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the window release switch. Is the repair complete? | -- | -- | |
12 | Backprobe a J 39200 DMM between ground and terminal E of the window release switch. Is continuity present? | -- | Go to Step 14 | Go to Step 13 |
13 | Locate and repair an open in CKT 1050 (BLK). Is the repair complete? | -- | -- | |
14 | Locate and repair an open in CKT 1576 (BLK). Is the repair complete? | -- | -- |